General-purpose workhorse optimized for workload accelerationMaximize your application performance with the PowerEdge R740 server, which brings you the perfect balance of accelerator cards, storage and compute resources in a 2U, 2-socket platform. With up to three 300W accelerator cards or six 150W cards, the R740 has the versatility to adapt to virtually any application and provides the optimum platform for VDI deployments. The R740 offers up to 16 x 2.5 or 8 x 3.5 drives and iDRAC9, so you can scale to meet demands and simplify the entire IT lifecycle.Ideal workloads VDI Private cloud Artificial intelligence Machine learning.
Other Specifications Download Specification | |
---|---|
Processor Configuration | Intel Xeon Gold 6148(2.40GHz/20-core/27.50MB/150W) |
Form Factor | Rack 2U |
Processor Make | Intel |
Max. Number Of Sockets Available On Chipset | 2 |
Max. Number Of Sockets Populated With Processor | 2 |
No. Of Processor | 2 |
Number Of Core Per Processor | 20 |
Chipset Compatible With CPU | C620 |
Motherboard (OEMcompatible With CPU) | Yes |
PCI Slots (Express Gen 3.0 Min.) | Up to 8 x Gen3 slots, Up to 4 x16 |
Max Nos Of PCI Lanes | 48 |
Memory ( DDR4 RAM Min.) | 128 GBRAM. DDR4 error checking and correcting (ECC) RDIMMs or load-reduced DIMMs (LRDIMMs) provide a maximum memory speed of 2666 MT/s , featuring high speed and availability. Server configured with 128GB RAM. GB |
DDR4 RAM Upgradable Upto (Minimum) | 3000. 24 DDR4 DIMM slots, Supports RDIMM /LRDIMM, speeds up to 2666, 3TB max Up to 12 NVDIMM, 192 GB Max Supports registered ECC DDR4 DIMMs only GB |
DIMM Slots (Minumum) | 24 DDR4 DIMM slots, Supports RDIMM /LRDIMM, speeds up to 2666, 3TB max Up to 12 NVDIMM, 192 GB Max Supports registered ECC DDR4 DIMMs only No. |
Hard Disk Drive Capacity | 1 TB Usable with RAID 5 ( 4 x 480GB SSD SAS Mix Use 12Gbps 512n 2.5in Hot-plug Drive, PX05SV,3 WPD,2628 TBW) GB |
Hard Disk Drive RPM With SAS (hot Plug Or Better ) | SSD SAS RPM |
RAID Controller Caches | 2Gb NV Cache. Offered controller have battery backed cache ( 2Gb NV). Dell PERC H730P+ RAID Controller, 2Gb NV Cache, Adapter, Full Heigh MB |
RAID Controller | RAID-0/1/10/5/6 |
RAID Controller Ports | 8 |
Video Controller (support VGA Or Above Resolution) | Yes |
Keyboard | standard |
Mouse | Optical scroll |
Bays (min. 2 Internal Or More Hot Plug) | Up to 16 x 2.5” SAS/SATA/SSD, max 60TB Up to 8 x 3.5” SAS/SATA, max 80TB |
USB Ports (version 2.0/3.0) | 5 Nos of USB 2.0/3.0 |
Certifications, Compliance & Support By Windows, Red Hat Or Novell. | Yes |
DVD ROM (or Better) | 8x or better |
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up | Yes |
FC HBA Dual Port Card | Available |
FC HBA Dual Port Card Speed | Server configured with dual adapter of dual port 16 Gbps Fiber Channel to external storage. |
Power Management | Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected |
Redundant Power Supply | Yes |
Redundant Fan | Yes |
Server Scalability To Be Achived Within The Box & Without Adding Nodes | NA |
Avaialbiklity Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. | No |
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. | No |
Test Report No. & Date | N/A. |
Name & Address Of Lab | N/A. |
BIS Registration No. Under CRS Of Deity | N/A. Additionl Features Failure Alerting Mechanism - The server is able to alert impending failures on server component to administrator in order Management Functionality - support for integrated management with remote presence, Server should be supplied with OEM Server Virtualization Support - Server supports latest version of virtualization software such as VMware, RHEV, Microsoft Hype Gartner - OEM in Leaders/Challengers in Gartners latest magic quadrant for servers |
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. | N/A. Redundant Fan - Server configured hot-swap redundant cooling fans with support N+1 redundancy. Fans are completely redundant so that failure of a fan should not impact the cooling inside the server chassis and will provide availability for business-critical applications |
Declare Max. Power Consumption Of The System | 750 Watts |
Availability Of Documentary Evidence In Support Of Model Quoted In Commersial Production & Due Evaluation Completed | Yes |
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. | Windows Server 2012/2012 R2/2016, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere ESXi |
Server Main Supply | 230V, ±10%,50 Hz |
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) | Yes |
RoHS Compliance | Yes |
Warranty | 3 years |