BATTERY CHARGER CONSTANT VOLTAGE CONSTANT CURRENT TYPE, 5 STATION, Voltage 12 Volts, Current per Station 12 Amps, No of station 5,Technology- SMPS, With experience of more than 20 years in the manufacturing of battery charges, we were the largest selling firm on the DGSND rate contract for this item, our customer includes BSF, CRPF, ITBP, SSB, CISF, NSG, State Police Forces and Indian Railways etc, OUR BATTERY CHARGERS PROVIDE UNMATCHED FEATURES INCLUDING - 1 horizontally design so that with the same length of cables, all the batteries on the floor can be charged with equal ease, the horizontal design also makes diagnostics and repairing easier as all the charging PCBs are easily visible and accessible from the top 2 PCBs has been designed, developed and produced in India and do not use any SMD components, hence repairing of charger is quite simple 3 Current is settable from 500 mA to 12 A in six discreet steps based on the rating of the battery available in the market, each step has its own over current protection, this ensures safety for any rating of the battery being charged on charger 4 the above features of over current protection for EACH step may not be available with chargers having a continuous dial instead of discrete selection , some chargers may only provide lesser steps 5 the reverse polarity protection and short circuit protection does not require replacement of fuse every time 6 our AC caballing is not dangerously exposed to outside environment.
Other Specifications Download Specification | |
---|---|
Charger Technology | SMPS Based |
Compatibility With Battery Type (User Selectable) | Lead acid & Tubular &VRLA-SMF |
Battery/battery Bank Voltage | 12 Volts |
Capacity Of The Battery To Be Charged(User Selectable) | 7 to 150 AH AH |
Maximum Charger Output Current | 12 Amp Amp |
Number Of Independent Charging Stations | 5 nos. Nos. |
Charging Cut-off Voltage Per 12V Battery | 14.5V +/- 0.2V Volts |
Input Voltage Range | 160 to 270 VAC VAC |
Efficiency | More than 75 % for SMPS at 230V % |
Ripple (Peak To Peak At Full Load) | Less than 100 mV millivolts |
Reverse Polarity Protection | Yes |
Short Circuit Protection | Yes |
Over Current Protection | Yes |
AC Surge Protection | with MOV |
Soft Start And Soft Stop Feature Without Inrush Current | Yes |
Over Voltage Cutoff Protection | Yes |
Facility For Charging Deep Discharged Battery Through Pulse Charging. | Yes |
Cut-in Voltage For Charging A Discharged Battery | 10.5V Volts |
Cut-off Voltage For Charging A Discharged Battery | 14.5V +/- 0.2V Volts |
Not To Charge Battery In Case One Or More Cells Are Internally Short/ Battery Voltage Less Than 10.5V | Yes |
Digital Display Of Output Voltage And Current | Yes |
LED Indication For Charging Status, Charged Condition Status And Reverse Polarity | Yes |
Cabinet Material | CRCA Sheet |
Cabinet Thickness | Min. 1.2mm mm |
Length Of Charging Cable For Each Station. | Min. 1.5 meter metre |
Size Of Charging Cable For Each Station. | 6 sq.mm sq. mm |
Minimum Operating Temperature | 0 degree celsius Degree Celsius |
Maximum Operating Temperature | 60 degree celsius Degree Celsius |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Conformity To The Specification. | Yes |
Type Test Report No. | ETDC (MH)/T&M/080 |
TTC Report Date | 29-09-2014 |
Name Of Lab | STQC-ETDC (Govt. of India Lab) |
Address Of Lab | B-108, Phase-8, Industrial Area, SAS Nagar, Mohali, Punjab |