The new Fluke Connect system of test tools communicates with the new Fluke Connect mobile app on your Android or iOS smart device, allowing you to share live measurements, monitor readings from safe distances, and get your job done easier than ever before --- 01. 3.5 digit display 02. Logging function for up to 65,000 readings 03.Can be used as a standalone or as part of the system 04. True rms wireless multimeter 05. Acts as a hub for other Fluke module tools 06. Voltage range AC/DC 600mV to 1000V 07. Current range AC/DC 60-400mA 08. Resistance range 600R to 50MR 09. Frequency range 99.99Hz-99.99kHz 10. Dimensions 207x93x48mm 11. Weight 340g.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 6000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.08 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 3 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 100 % |
Capacitance Mreasurement Range | 1 to 100 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -40 to 400 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category II 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | -10*C to +50*C |
Operating Humidity (RH) | 90% to 35*C, 45% to 40*C, 45% to 50*C |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 2AA, Neda 15A, IEC L86 |
Total Voltage Of Battery | NA |
Standard Accessories Supplied With The Equipment | Users manual, Leads etc. |
Dimensions (H X W X L) | 207x93x48mm mm x mm x |
Weight | 340gm gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | NA |
Test Report Date | NA |
Name Of The Lab | NA |
Warranty | 3 Year |