Sparaquant spectrometer proove 300 Measuring technology Spectrophotometer with reference beam technology Wavelength range UV 190 1100 nm Lamp type Xenon flash lamp Ambient light protection Measurement with open shaft.Live ID System 2-D Barcode recognition for cell tests and reagent tests. Barcode contains lot, expiry, and calibration data. Data stored with each measurement Cell recognition Automatic Cell recognition by system sensors Cell holder Cell holder is easily removable for cleaning purpose3 Level AQA check AQA Prime Individual settings for all methods in AQA 1 instrument check and AQA 2 mode system check and pipette check Sample matrix Easy access through setting menu to perform instrument supported matrix check for each method For Project laboratory with accessories 2 copy Manual including installation and demo n training at laboratory..
Other Specifications Download Specification | |
---|---|
Spectrophotometer Type | Microprocessor Based |
Display | High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC |
Monochromator | Concave holographic grating with 1200 lines/mm |
Wavelength Range (user Selectable) | 340-960 nm |
Wavelength Resolution | 0.2 nm |
Wavelength Accuracy | +-1 nm |
Repeatability | +-1 nm |
Spectral Bandwidth | < 2 |
Type Of Detector | Photodiode |
Measuring Modes | Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards. |
Operating Mode | Single wavelength: Measuring 1, ABS and CONC |
Light Source | Tungstan Halogen Lamp |
Power | 230 V +- 10 50Hz |
Standard Accessories To Be Supplied | 10 nm path length four (4 nos.) Cuvettes matched with 3 percent |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | IQNET CERT. NO. 005356 QM08 |
Power Requirements | 230 V +- 10, 50 Hz |
Operating Temperature | 15-35 Degree C |
Operating Humidity (RH) | 30-80 % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" | IQNET CERT. NO. 005356 QM08 |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | NA |
Test Report No. | NA |
Test Report Date | NA |
Name Of The Lab | NA |
Warranty | 1 Year |