× All the transactions performed on 2.0 is available here. To access Market click "Home".

perfect-prime aq9600, pm 0.3-2.5-10 um air quality particle dust detector or counter (n and m)(nm-pc141)

` 42,999.00

  • MRP: `50000.00

Test particle size 0.3m/2.5m/10.0m. Light source Semiconductor lasers. Accuracy 5. Temperature range-050 /32122. Accuracy 5. Humidity range 0100 RH Accuracy 2 RH Display 320240 2.8 in LCD display Counting efficiency 10010@0.5m Sampling Custom 1s 59min. 59s Sampling frequency 199/Continuous Alarm levels 1100,000 FED209 E Standard 29ISO14464-1Standard Test mode Single/repeat/continuous/timer/Average Data Storage 2000 Interface 9V / 500 mA power supply and charging Operating environment 545, 90 RH Storage environment-2060, 90 RH..

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • pH Range - 0.00 to 14.00 pH
  • Resolution - 0.01 pH
  • Accuracy - +- 0.05 pH
  • Modes - pH mV- C
  • Temperature Compensation Range - 0 to 100 Degree C
Other Specifications Download Specification
Type Microprocessor Based
PH Range 0.00 to 14.00 pH
Resolution 0.01 pH
Accuracy +- 0.05 pH
Calibration up to 3 points with auto buffer
Modes pH mV- C
Display LED / LCD / Touch Screen, 3 digits
Temperature Compensation Type Automatic
Temperature Compensation Range 0 to 100 Degree C
Temperature Accuracy +- 0.3 Degree C
Parallel Temperature Indication Yes
Storage Pocket For PH Electrode Yes
System To Be Supplied With Measuring Electrode Combined (glass Calomel), Temperature Probe, Electrode Stand, Calibration Buffer And Maintenance Kit, Operation Manual, Power Cable And Plug. Yes
Ingress Protection (Water Tight) As per OEM
Impact Resistant Yes
Corrosion Resistant Yes
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " CE
Power Requirements 230 V +- 10, 50 Hz AC
Operating Temperature 0-50 Degree C
Operating Humidity (RH) 0-100 %
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer) As per OEM
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) As per OEM
Test Report No. As per OEM
Test Report Date As per OEM
Name Of The Lab As per OEM
Warranty 1 Year

Price Dekho Price Dekho Price List in india