× All the transactions performed on 2.0 is available here. To access Market click "Home".

inverter (luminous)(860)

` 5,670.00

  • MRP: `6300.00

This product use for extra lighting backup..

  • Availability: 99 In Stock
  • Min. Qty. Per Consignee: 1
  • ISI marked - NO
  • If ISI marked yes, CM/L No. - NA
  • Mode of operation - Stand-alone
  • Inverter's output wave form - Pure sine wave
  • Total Harmonic distortion - 0 %
Other Specifications Download Specification
Rating Of Inverter 688 KVA
ISI Marked NO
If ISI Marked Yes, CM/L No. NA
Mode Of Operation Stand-alone
Nos. Of Phase single
Inverter's Output Wave Form Pure sine wave
Inverter Efficiency 688
Switching Device MOSFET
Total Harmonic Distortion 0 %
Operating AC Voltage Range 220 Volts
Operating Frequency Range 100 Hz
Operating Temperature NA degree cel
Operating Relative Humidity NA %
Load Power Factor AS REQUIRED
Maximum Power Point Tracking(MPPT) yes
Galvanic Isolation Between Input DC & Output AC yes
Ingress Protection Rating Of Inverter IP 65 for outdoor use
Built In Protection For AC High/low Voltage & Frequency If Connected To AC Mains IP 65 for outdoor use
Output Regulation At Rated Voltage Yes
By-pass Facility If Connected To AC Mains IP 65 for outdoor use
Over Load Protection 110% For 60 Seconds ,125% For 30 Seconds And 150% For 5 Seconds yes
Display Type LED
Display Parameters Like DC Voltage(V),DC Current (A), AC Voltage (V) YES
Conformity Of Inverter To Environmental Testing Conditions As Per IEC 600688-2 (1,2,14,30) Or Equivalent BIS Standard YES
Sequence Of Power Drawing 1. SPV 2. AC Mains( if connected with AC power) 3. Battery bank
Nos. Of Modules In An Array NA NOS.
Rating Of Individual PV Module NA Wp
Efficiency Of Solar Panel NA %
Reverse Polarity Protection For PV Modules yes
90% Performance Warranty For SPV 10 years
80% Performance Warranty For SPV 25 years
Salt Mist Corrosion Resistant Material For Body & Frame Of SPV Module Aluminium
Area Required For Installation Of Solar Pannels With Mounting Structure AS REQUIRED sq. mt
TTC For PV Module From Any MNRE Lab As Per MNRE 2015-2016 yes
Test Report Number NA
Date Of Test Report NA
Name And Address Of Laboratory NA
OEM Test Report For Indigenously Produced PV Module(s) yes
Provision For Solar Generation Meter yes
Provision For Bidirectional Meter(Net Meter) yes
Provision Of Anti Rusting/ Non Corrosive Mounting Structure yes
Material Of Mounting Structure Stainless steel
Sustainability Of Wind Speed. 150 KM/Hr
Type Of Battery VRLA KM/Hr
Battery Backup Time At Rated Load 1 Hour
Battery Bank Voltage 12 Volt
Capacity Of Battery Bank 12 VAH
3 Stage Battey Charging ( Float, Boost & Equalize Stage ) For Long Life Of The Battery yes
Reverse Polarity Protection yes
Complete Installation Work To Be Done By Supplier yes
Gross Weight Of The Inverter 4 to 5 kg
Availability Of Type Test Report For Inverter Including Environmental Tests From Central Government/NABL/ILAC Accridiated Laboratory To Prove Conformity To The Specification yes
Test Report Number NA
Date Of Test Report NA
Name And Address Of Laboratory NA
Type Test Report To Be Furnished On Buyers Demand yes