oWe are the manufacturers of Ni-Cd battery charger 12 V DC24V DC26V DC for STAR-V-Set. The charger has been specifically manufactured for installation with STAR-V-Set of the Army. The equipment has been tried by a number of Army units and found very useful. It has following advantages as compared to the Float Charger being used presently with AC Voltage oIts size has been specifically designed to fit perfectly anywhere. oThis Equipment releases fine quality DC Voltage for Ni-Cd-Battery.o It takes 10-15 minutes to charge the battery.oThe equipment prepare for Mark-1-A12V, Mark-2-B-24 V, Mark-1-26V,oThe equipment require 220 V AC or Provision from our Veh either running or not.oThe Equipment shows one Amps-Meter, one Volt-meter.oThe Equipment shows one selector switch for volt and Amps.oThe equipment has three port and used all or one at a time.oThe equipment has provision for switch off any port any time.o Indicator for CHG. and Output Voltage Terminals..
Other Specifications Download Specification | |
---|---|
Charger Technology | Transformer Based |
Compatibility With Battery Type (User Selectable) | VRLA-SMF |
Battery/battery Bank Voltage | 12 Volts |
Capacity Of The Battery To Be Charged(User Selectable) | As Per OEM AH |
Maximum Charger Output Current | 5 Amp |
Number Of Independent Charging Stations | 3 Nos. |
Charging Cut-off Voltage Per 12V Battery | 24 Volts |
Input Voltage Range | As Per OEM VAC |
Efficiency | 90 % |
Ripple (Peak To Peak At Full Load) | As Per OEM millivolts |
Reverse Polarity Protection | Yes |
Short Circuit Protection | Yes |
Over Current Protection | Yes |
AC Surge Protection | with MOV |
Soft Start And Soft Stop Feature Without Inrush Current | Yes |
Over Voltage Cutoff Protection | Yes |
Facility For Charging Deep Discharged Battery Through Pulse Charging. | Yes |
Cut-in Voltage For Charging A Discharged Battery | As Per OEM Volts |
Cut-off Voltage For Charging A Discharged Battery | As Per OEM Volts |
Not To Charge Battery In Case One Or More Cells Are Internally Short/ Battery Voltage Less Than 10.5V | Yes |
Digital Display Of Output Voltage And Current | Yes |
LED Indication For Charging Status, Charged Condition Status And Reverse Polarity | Yes |
Cabinet Material | CRCA Sheet |
Cabinet Thickness | As Per OEM mm |
Length Of Charging Cable For Each Station. | As Per OEM metre |
Size Of Charging Cable For Each Station. | As Per OEM sq. mm |
Minimum Operating Temperature | As Per OEM Degree Celsius |
Maximum Operating Temperature | As Per OEM Degree Celsius |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Conformity To The Specification. | Yes |
Type Test Report No. | As Per OEM |
TTC Report Date | As Per OEM |
Name Of Lab | As Per OEM |
Address Of Lab | As Per OEM |