A manometer is one of the earliest instruments used to measure the pressure of a fluid. It is widely used even today because of its accuracy plus its simplicity to operate. But the traditionally used liquid manometer has limitations. It cannot be collaborated with a computer or monitoring device. Moreover, the glass tubes often break leaving the whole device useless. Such limitations can be overcome with digital manometers. This digital manometer is microprocessor-based and available in a convenient, portable size for ease of use in the field. It has a large dual LCD with backlight. It comes with data hold feature for storage of data. This is a higher accuracy digital manometer that is used to calibrate pressure transmitters and other pressure instruments. It requires no external devices to work and provides efficient results quickly. This digital manometer works by measuring and comparing the weights of fluids or gases between two different pressures..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 3 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 100 % |
Capacitance Mreasurement Range | 1 to 100 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -40 to 400 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | NA |
Safety Rating | Category IV 600 V of IEC 61010 |
Overload Protection | Through Fuse |
Operating Temperature Range | 0°C-40°C |
Operating Humidity (RH) | 85 |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 9.0, 6F22 |
Total Voltage Of Battery | 1x9.0 |
Standard Accessories Supplied With The Equipment | As per OEM |
Dimensions (H X W X L) | 185 x 93 x 35 mm x mm x |
Weight | 300 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | As per OEM |
Test Report Date | As per OEM |
Name Of The Lab | As per OEM |
Warranty | 1 Year |