Accuracy 2mH Resolution 1uH Accuracy 20mH Resolution 10uH Accuracy 200mH Resolution 100uH Accuracy 2H Resolution 5.0 percent5 1mH Accuracy 20H Resolution 5.0 percent5 10mHAccuracy 2nF Resolution 1pF Accuracy 20nF Resolution 10pF Accuracy 200nF Resolution 100pF Accuracy 2uF Resolution 1nF Accuracy 20uF Resolution 10nF Accuracy 200uF Resolution 5.0 percent5 100nFAccuracy 1000uF Resolution 5.0 percent25 1uFAccuracy 200 Resolution 0.8 percent50.1 Accuracy 2K Resolution 1 Accuracy 20K Resolution 10 Accuracy 200K Resolution 100 Accuracy 2M Resolution 1K Accuracy 20M Resolution 1.0 percent1510K. LCR Meter, Hand Held 3.5 Dgt., Inductance , Capacitor , Resistance.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.08 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 3 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 200 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -40 to 400 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0-45 |
Operating Humidity (RH) | 95 |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CE |
If Battery Operated, Type And No. Of Battery | 1.5V*2 (AAA) |
Total Voltage Of Battery | 3 V (1.5 V × 2) AA alkaline batteries |
Standard Accessories Supplied With The Equipment | Test Lead, Battery Manual, Gift Box |
Dimensions (H X W X L) | 185 x 91x 49 mm x mm x |
Weight | 408 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 25662 |
Test Report Date | 11-08-2017 |
Name Of The Lab | Metro Q |
Warranty | 1 Year |