nanodrop micro volume spectrophotometer (thermo fisher scientific)(nanodrop one)

` 939,250.00

  • MRP: `1105000.00

Instrument Control Built-in touchscreen,Minimum Sample Volume 2 L,Limit of Detection dsDNA Pedestal 2.0 ng/LMaximum Concentration dsDNA Pedestal 27,500 ng/L, BSA IgG Pedestal 820 400 mg/mL,Measurement and Data Processing Time 8 seconds,Wavelength Range 190850 nm,Accuracy 1 nm,Photometric Range 10 mm equivalent,Accuracy 3 at 0.97 A, 302 nm,Resolution Spectral Bandwidth 1.8 nm Pathlength 0.030 to 1.0 mm auto-ranging,Light Source Xenon flash lamp,Detector 2048-element CMOS linear image sensor,Dimensions W D H 20 25.4 32.3 cm,Weight 3.6 kg,Power Consumption Operating 1218 W,Standby 5 W,Temperature Control cuvette only 37 C.

  • Availability: 2 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC
  • Monochromator - Concave holographic grating with 1200 lines/mm
  • Wavelength Range (user selectable) - 340-960 nm
  • Wavelength Accuracy - +-1 nm
  • Type of Detector - Photodiode
Other Specifications Download Specification
Spectrophotometer Type Microprocessor Based
Display High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC
Monochromator Concave holographic grating with 1200 lines/mm
Wavelength Range (user Selectable) 340-960 nm
Wavelength Resolution 0.2 nm
Wavelength Accuracy +-1 nm
Repeatability +-1 nm
Spectral Bandwidth < 2
Type Of Detector Photodiode
Measuring Modes Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards.
Operating Mode Single wavelength: Measuring 1, ABS and CONC
Light Source Tungstan Halogen Lamp
Power 230 V +- 10 50Hz
Standard Accessories To Be Supplied 10 nm path length four (4 nos.) Cuvettes matched with 3 percent
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " CE
Power Requirements 230 V +- 10, 50 Hz
Operating Temperature 40 Degree C
Operating Humidity (RH) Normal %
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" Yes
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. QM/1606TU
Test Report Date 02.06.16
Name Of The Lab In House
Warranty 1 Year