amprobe amb 55- 5kv insulation resistance tester (amprobe)(amb 55)

` 189,423.00

  • MRP: `212500.00

Amprobe AMB 55- 5KV insulation resistance Tester along with standard Accessories.

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 200 K Ohm to 1 T Ohm
  • Test Voltage - 250, 500, 1000, 2500 and 5000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Portable
Measurement Range 200 K Ohm to 1 T Ohm
Test Voltage 250, 500, 1000, 2500 and 5000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection Inhibit test terminal voltage >30 V prior to initialization of test
Pass Fail Function Yes
Data Logging more than 99 locations
Software Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 2 milliamper
Operating Temperature Range -10 °C - 50 °C (14° - 122°F) Degree C
Operating Humidity (RH) 90% RH %
Power Requirements Battery Operated
Type Of Battery Ni-MH rechargeable batteries
PC Interface Available
Standard Accessories Supplied With The Equipment Test lead,large jaw alligator clips, batteries, users manual,carrying case,software,RS-232 cable, USB cable
Dimensions (H X W X L) 310* 130 * 250 mm x mm x
Weight 3000 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. Provided at the time of supply
Test Report Date Provided at the time of supply
Name Of The Lab Provided at the time of supply
Warranty 2