waterproof hand-held meters for ph (lovibond)(sd 300)

` 110,000.00

  • MRP: `125000.00

Min / Max Value Memory highest and lowest measured value is saved.Auto Hold freeze and display measurement. Auto Power Off if unused, the meter automatically switches off after a selected period 0 to 120 min, or deactivated Additional Display for pH Electrode and Battery Bar graph displayLow Battery Display BAT Automatic Temperature CompensationAutomatic Temperature Compensation ATC in pH mode in the range of 0 105 C when the temperature probe is connected. Temperature can be input manually, when the temperature probe is not attached.pH Calibration Automatic Buffer Recognition. Permissible electrodes data Asymmetry 55mV/Slope4562mV/pH The condition of pH Electrode is checked at each calibration. 1, 2 or 3 point calibration with Lovibond Standard Buffer, DIN 19266 Buffer or any manually entered Buffer values..

  • Availability: 75 In Stock
  • Min. Qty. Per Consignee: 1
  • pH Range - 0.00 to 14.00 pH
  • Resolution - 0.01 pH
  • Accuracy - +- 0.05 pH
  • Modes - pH mV- C
  • Temperature Compensation Range - 0 to 100 Degree C
Other Specifications Download Specification
Type Microprocessor Based
PH Range 0.00 to 14.00 pH
Resolution 0.01 pH
Accuracy +- 0.05 pH
Calibration up to 3 points with auto buffer
Modes pH mV- C
Display LED / LCD / Touch Screen, 3 digits
Temperature Compensation Type Automatic
Temperature Compensation Range 0 to 100 Degree C
Temperature Accuracy +- 0.3 Degree C
Parallel Temperature Indication Yes
Storage Pocket For PH Electrode Yes
System To Be Supplied With Measuring Electrode Combined (glass Calomel), Temperature Probe, Electrode Stand, Calibration Buffer And Maintenance Kit, Operation Manual, Power Cable And Plug. Yes
Ingress Protection (Water Tight) 67
Impact Resistant Yes
Corrosion Resistant Yes
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " Yes
Power Requirements 230 V +- 10, 50 Hz AC
Operating Temperature 30 Degree C
Operating Humidity (RH) 80 %
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) NA
Test Report No. NA
Test Report Date NA
Name Of The Lab NA
Warranty 1 Year