The analyzer should be able to measure blood gas pH, pO2, pCO2, electrolytes Na,K,Ca,Cl-,Metabolites-Glucos,Lactate, Saturation Oxygen ,Hemoglobin and more than 45 derived parameters. Minimum 5 programmable options for sample measurement mode with different parameter configuration as per the user requirement. The instrument should perform on board automated ampoule quality control The instrument should provide ACID BASE chart/graph for assisting clinical interpretation. The instrument should be user friendly and inbuilt onboard training tools. Automated capillary sample volume determination and subsequent parameter measurement. Analyser should have onboard help system vis multimedia video tutorials. Onboard facility automated ampoule quality control with anytime removal and loading. The instrument should be operated with conventional individual reagents like Calibration solutions, rinse / cleaning reagents etc. The instrument should have onboard gas bottles, N.
Other Specifications Download Specification | |
---|---|
System Is Capable To Measure Alkali And Alkaline Earth Metals (Sodium, Potassium, Calcium, Lithium) In The Samples | Yes |
Ignition System | Auto ignition |
Analyzed Elements | Na+, Ca++, K+, Li+ |
Accuracy | Less than +- 2 % |
Reproducibility | Less than +- 2 % |
Sensitivity | Na+ = 1 ppm, Ca++ = 15 ppm, K+ = 1 ppm, Li+ = 1 ppm |
Display | at least 3 lines LCD |
Detector | Photo conductive cell |
Filters | Sodium, Potassium, Calcium, Lithium |
Aspiration Rate | 3 to 6 ml/min |
Memory | To store and recall 800 samples |
Type Of Printer Interface For Printing Of Samples | thermal printer |
Accessories | Compressor with built in air regulator and air filter |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | ce |
Power Requirements | 230 V +- 10, 50 Hz AC |
Operating Temperature | 15-30 degree Degree C |
Operating Humidity (RH) | 20-80% % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" | NA |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | NA |
Test Report No. | NA |
Test Report Date | NA |
Name Of The Lab | NA |
Warranty | 1 Year |