The SDS2000X series employs a new generation of SPO technology. It has an innovative digital trigger system with high sensitivity and low jitter, and a maximum waveform capture rate of 140,000 wfm/s normal mode, up to 500,000 wfm/s sequence mode. It also employs not only the common 256-level intensity grading display function but also a color temperature display mode. The trigger system supports multiple powerful triggering modes including serial bus triggering. History waveform recording and sequence acquisition allow for extended waveform records to be captured, stored, and analyzed. An impressive array of measurement and math capabilities, options for a built-in 25 MHz arbitrary waveform generator, 16 digital channels MSO, as well as serial decoding are also features of the SDS2000X..
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 4 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 500mV per Div to 10 V/div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, Ground |
Time Base Range | 2 ns/div to 50 s/div |
Trigger Types | Edge, Slope, Pulse Width, Video, Window, Interval, Dropout, Runt, Pattern, Serial |
Measurements | 37 Types of Automatic Measurements of Time, Voltage and Delay. Math Function - Add, subtract, multiply, divide, FFT, Integration, Differentiation, Square Root |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Auto, Normal, Peak Detect, Average, Enhance Resolution (Eres), Single |
Display Type | Colour |
Display Size | 20.3 CM |
I/O Interface | USB Host, USB Device, LAN, Pass/Fail, Trigger Out |
Standard Accessories To Be Supplied | 4 no. Passive Probe, Power Cord, CVD (Including User Manual and EasyScopeX software), Quick Start, Calibration Certificate, USB Cable |
Operating Temperature Range | 10 degC to 40degC Degree C |
Operating Humidity (RH) | 85% RH % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | 20160128001 |
Test Report Date | Jan 28, 2017 |
Name Of The Lab | Siglent |
Warranty | 3 Year |
Real Time Bandwidth | 300 MHz |
Record Length Per Analog Channel Simultaneously | 70 Mega Point |
Sample Rate Per Analog Channel Simultaneously | 1 GS/sec |
Waveform Update Rate | 140000 Waveforms/ |
Time Base Accuracy | 25 PPM |