Multi function Model, 4 Digit 6000 Count display, Low Pass Filter, Voltage Detector DC voltage 600.0mV to 1000V, Basic Accuracy 0.3 percent rdg, AC Voltage 6.000V to 1000V, Bandwidth 40 Hz to 1 KHz, AC/DC current 6.00A / 10 Amp, Frequency up to 99.99 kHz, Resistance 60.00 Meg Ohm, Voltage detection function, Capacitance up to 1.00 micro farad to 10.00 mF, Accessories LR03 Alkaline Batteries x 4nos,Test Lead, Holster, Instructional Manual. The Prices include GST @ 18 percent. Delivery Period is 4-6 weeks..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 6000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | .05 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 1 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 100 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | NA % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category IV 600 V of IEC 61010 |
Overload Protection | Through Fuse |
Operating Temperature Range | 30 degree |
Operating Humidity (RH) | 70% |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CE |
If Battery Operated, Type And No. Of Battery | AAA |
Total Voltage Of Battery | 6V |
Standard Accessories Supplied With The Equipment | Test Leads, Holster, Instructional Manual, Batteries LR03 x 4 |
Dimensions (H X W X L) | 84mm (W) x 174mm (H) x 52mm (D) mm x mm x |
Weight | 390 g gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | NTS/G/L-00725 |
Test Report Date | 17.7.2017 |
Name Of The Lab | NABL |
Warranty | 1 Year |