SDG1000 series Function/Arbitrary Waveform Generator is a new family member of SIGLENT with friendly design 3.5 inch TFT-LCD display Built-in Chinese/English language Online help function Support USB and internal storage, facilitate files management Special connection terminal for grounding. Enables edition of 14-bit 16kpts arbitrary output waveforms, Arbitrary editing software EasyWave provides 9 standard waveforms Sine, Square, Ramp, Pulse, ExRise, ExpFall, Sinc, Noise and DC, which meets all engineers basic needs In addition, it provides plenty of ways of manual drawing, point-to-point line drawing and arbitrary point drawing. It facilitates to create complex waveforms Multi-file screen management helps users to edit multiple-waveform simultaneously. It provides 10 Storage in non-volatile RAM. You can edit and store more waveforms by EasyWave..
Other Specifications Download Specification | |
---|---|
Frequency Bandwidth (Sine Wave) | 10 mHz to 25 MHz |
No. Of Channels | 2 |
Standard Waveforms | Sine, Square, Pulse, Ramp, Noise, Sin(x)/x, Exponential rise/fall, Gussian, DC Offset |
Band Width Of Arbitrary Waveform Generator | 10 mHz to 5 MHz |
Sample Rate Of Arbitrary Waveform Generator | 50 Mega Samples/sec |
Record Length Of Arbitrary Waveform Generator | 16 Kilo Points |
Waveform Memory Of Arbitrary Waveform Generator | 4 Waveforms |
Vertical Resolution (Minimum) | 12 Bits |
Amplitude Range (at 50 Ohm Impedance) | 10 mV to 10 V pp |
Modulation | AM, FM, PM, FSK, Burst, PWM |
Interface | USB |
Display | Colour |
Standard Accessories (To Be Supplied) | Quick Start, Calibration certificate, CD (EasyWave computer software), Power Cord, USB Cable |
Power Requirements | 230 V +/-10% AC, 50 Hz +/- 3% |
Operating Temperature Range | 0 degC to 40 degC Degree C |
Operating Humidity (RH) | 90% RH at 35 degC % |
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. (Test Reports Are To Be Furnished When Demanded By Buyer)" | Yes |
Test Report No. | 20160128001 |
Test Report Date | Jan 28, 2017 |
Name Of The Lab | Siglent |
Warranty | 3 Years |