BATTERY CHARGER CONSTANT VOLTAGE CONSTANT CURRENT TYPE, 5 STATION, Voltage 12 Volts, Current Per Station 12 Amps, No. of Station 5, Technology-SMPS, With Experience of More Than 8 Years in the Manufacturing of Battery Chargers, We were the Largest Selling Firm on the DGSND Rate Contract For this Item, Our Customer Includes Major Department Like BSF, CRPF, ITBP, SSB, CISF, NSG, State Police Forces And Indian Railways Etc..
Other Specifications Download Specification | |
---|---|
Charger Technology | SMPS Based |
Compatibility With Battery Type (User Selectable) | Lead acid & Tubular &VRLA-SMF |
Battery/battery Bank Voltage | 12 Volts |
Capacity Of The Battery To Be Charged(User Selectable) | 7 To 150 AH AH |
Maximum Charger Output Current | 12 Amp |
Number Of Independent Charging Stations | 5 Nos. |
Charging Cut-off Voltage Per 12V Battery | 14.5V +/-0.2V Volts |
Input Voltage Range | 160 To 270 VAC |
Efficiency | More Than 75% For SMPS At 230V % |
Ripple (Peak To Peak At Full Load) | Less Than 100 MV millivolts |
Reverse Polarity Protection | Yes |
Short Circuit Protection | Yes |
Over Current Protection | Yes |
AC Surge Protection | with MOV |
Soft Start And Soft Stop Feature Without Inrush Current | Yes |
Over Voltage Cutoff Protection | Yes |
Facility For Charging Deep Discharged Battery Through Pulse Charging. | Yes |
Cut-in Voltage For Charging A Discharged Battery | 10.5 Volts |
Cut-off Voltage For Charging A Discharged Battery | 14.5V +/-0.2V Volts |
Not To Charge Battery In Case One Or More Cells Are Internally Short/ Battery Voltage Less Than 10.5V | Yes |
Digital Display Of Output Voltage And Current | Yes |
LED Indication For Charging Status, Charged Condition Status And Reverse Polarity | Yes |
Cabinet Material | CRCA Sheet |
Cabinet Thickness | Min. 1.2 mm mm |
Length Of Charging Cable For Each Station. | Min. 1.5 Meter metre |
Size Of Charging Cable For Each Station. | 6 Sq. MM sq. mm |
Minimum Operating Temperature | 0 Degree Celsius Degree Celsius |
Maximum Operating Temperature | 60 Degree Celsius Degree Celsius |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Conformity To The Specification. | Yes |
Type Test Report No. | ETDC (MH)/T & M/079 |
TTC Report Date | 29-09-2014 |
Name Of Lab | STQC-ETDC (Govt. Of India Lab) |
Address Of Lab | B-108, Phase-8, Industrial Area, SAS Nagar, Mohali, Punjab |