× All the transactions performed on 2.0 is available here. To access Market click "Home".

fluke 190-204 (fluke)(fluke 190-204 oscilloscope)

` 590,532.00

  • MRP: `656147.00

Fluke 190-204/S Measurements - V dc, V ac rms, V ac plus dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac plus dc, frequency in Hz, rise time using cursors, fall time using cursors, Power Factor PF, Watts, VA, VA reactive, phase between any 2 inputs, pulse width pos./neg., duty cycle pos./neg., temperature C, temperature F not for Japan, dBV, dBm into 50 I and 600 I, VPWM ac and VPW Mac plus dc for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ration 190-xx2 only, FFT, One mathematical operation on any 2 input channels add/subtract/multiply X-Y-mode Frequency Spectrum using FFT analysis. Display Size - 127 mm x 88 mm 153 mm/6.0 in diagonal LCD, Vertical Sensitivity 2 mV/div to 100 V/div, plus variable attenuation , Time Base Accuracy PPM - Plus minus 0.01 percent of reading plus 1 pixel, Frequency Spectrum using FFT analysis , Power Supply -Mains adapter/battery charger BC190 included, version depending of country WITH 3 YEARS WARRANTY..

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 1
  • Operating System - Non -Windows
  • Bandwidth Upgradability - Yes
  • No. of Analog Channels - 4 Number
  • No. of Digital Channels - NA Number
  • Min. Detectable Pulse Width - 8 ns peak detect on each channel ns
Other Specifications Download Specification
Type Digital
Operating System Non -Windows
Bandwidth Upgradability Yes
No. Of Analog Channels 4 Number
Digital Channels No
No. Of Digital Channels NA Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width 8 ns peak detect on each channel ns
Memory Upgradability Yes
Segmented Memory Feature Availability Yes
Vertical Sensitivity 2mV/Div to 5 V/Div
Vertical Resolution 8 bits
Coupling AC or DC, with ground level indicator
Time Base Range "2 ns/div to 4 s/div"
Trigger Types "Automatic Connect-and-View™, free run, single shot, edge, delay, dual slope, video, video line, selectable pulsewidth (channel A only), N-cycle"
Measurements Yes it will be provided and details are given in product description
Frequency Analysis Feature Yes
In-built Frequency Counter No
In-built Function Generator No
Acquisition Modes "Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay"
Display Type Colour
Display Size 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD CM CM
I/O Interface USB and Pendrive
Standard Accessories To Be Supplied BP291 (4800 mAh), VPS410-x (one red, one grey, one blue, one green), Battery charger (BC190), Hangstrap, Handstrip (user selectable for left- or right hand use), Multi-language users manuals on CD-ROM, FlukeView® demo package (with restricted functionality), and USB interface cable for PC connectivity
Operating Temperature Range 0 °C ~ +40 °C; 0 °C ~ +50 °C excluding battery Degree C Degree C
Operating Humidity (RH) " +10 °C ~ +30 °C: 95 % RH non-condensing +30 °C ~ +40 °C: 75 % RH non-condensing +40 °C ~ +50 °C: 45 % RH non-condensing" % %
Power Supply 230V +- 10% , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. standard
Test Report Date standard
Name Of The Lab standard
Warranty 3 Year
Real Time Bandwidth 200 MHz
Record Length Per Analog Channel Simultaneously "10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord™ Roll mode" Mega Point Mega Point
Sample Rate Per Analog Channel Simultaneously "2.5 GS/s (2ch) for each channel 1.25 GS/s (4ch)" GS/sec GS/sec
Waveform Update Rate Available Waveforms/
Time Base Accuracy 0.05 PPM

Price Dekho Price Dekho Price List in india