SDM3065X is a 6-1/2 digit digital 2,200,000 count multimeter incorporating a dual display and is especially well suited for the needs of high-precision, multifunction and automatic measurement..
Other Specifications Download Specification | |
---|---|
Type | Benchtop |
Display | 6.5 Digit |
Measurement Type | True RMS |
Count | 200000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.08 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 100 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 100 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -40 to 400 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category II 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0 degC to 50 degC |
Operating Humidity (RH) | 80% RH at 40degC |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | NA |
Total Voltage Of Battery | NA |
Standard Accessories Supplied With The Equipment | Power Cord, Test Lead with Alligator Clips, USB Cable, Quick Start, CD (EasyDMM computer software) |
Dimensions (H X W X L) | 107.21 x 260.29 x 345.45 mm x mm x |
Weight | 4 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 20160128001 |
Test Report Date | Jan 28, 2017 |
Name Of The Lab | Siglent |
Warranty | 1 Year |