70MHz Bandwidths, 1GSa/s Real Time Sample Rate, Trigger Mode Edge/ Pulse Width/ Video/ Slop/ Overtime/ Alternative Trigger etc., Provides Software for PC Real-time Analysis, Five Math Functions and FFT functions, 32 Automatic Measurements and Track Measurement via Cursor Automatically, Large 7 inch Color Display, WVGA 800 x 480, Support U Disk and Local Files Storage, Pass / Fail Function Enables to Output Testing Results.
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 2 Number |
Digital Channels | No |
No. Of Digital Channels | 8 Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | na ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | No |
Vertical Sensitivity | 2mV/Div to 5 V/Div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, GND |
Time Base Range | 20ns - 10s |
Trigger Types | Edge, Pulse Width, Video, Slop, Overtime, Alternative Trigger |
Measurements | Five Math Functions, +, -, , /, and FFT functions |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | Yes |
Acquisition Modes | Normal, Peak Detect, Average |
Display Type | Colour |
Display Size | 17.78 CM |
I/O Interface | usb |
Standard Accessories To Be Supplied | 2 Probes, Manual, Power Chord |
Operating Temperature Range | 0 to 50C Degree C |
Operating Humidity (RH) | 000 % |
Power Supply | 230V +- 10 , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | 0003 |
Test Report Date | 01-02-2018 |
Name Of The Lab | APLAB |
Warranty | 1 Year |
Real Time Bandwidth | 70 MHz |
Record Length Per Analog Channel Simultaneously | 24K Mega Point |
Sample Rate Per Analog Channel Simultaneously | 4ns/div to 40s/div, in a 2,4,8 sequence GS/sec |
Waveform Update Rate | NA Waveforms/ |
Time Base Accuracy | 30 PPM |