Three Phase Power Quality Analyzer with Power Wave data capture,Power inverter efficiency,Energy monetization,Energy assessment,Frontline troubleshooting,Predictive maintenance,Long-term analysis ,Load studies,Highest safety rating in the industry 600 V CAT IV/1000 V CAT III rated for use at the service entrance,Measure all three phases and neutral With included four flexible current probes with enhanced thin flex design to fit into the tightest places,Automatic Trending,System-Monitor,View graphs and generate reports With included analysis software,Battery life Seven hours operating time per charge on Li-ion battery pack.Wireless data download, Three Years Warranty, Includes NABL Calibration report..
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Three phase |
Display Type | LCD Backlit |
Display Mode | Scope, Meter, Trend |
Number Of Current Channels | 04 Nos. |
Number Of Voltage Channels | 05 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 0.0 Volt to 1000 Volt Volts |
Measurable Voltage Accuracy | ± 0.1% |
Measurable Voltage Resolution | 0.01 Volt Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 6000A Ampere |
Measurable Current Accuracy | ± 0.5% ± 5 counts, |
Measurable Current Resolution | 0.1A Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 6000000 KW KW |
Power Accuracy | ± 1% ± 10 counts |
Power Resolution | 0.1 Watt Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 42.500 Hz - 69.000 Hz Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | ± 2.5 % |
Resolution In Measurement Of Total Harmonics Distortion | 0.1% |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | 50 |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | ± 0.1 % |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | ± 2.5% |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | NA |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 1.0-2.8 |
Measurable Crest Factor Accuracy | ± 5% |
Measurable Crest Factor Resolution | 0.01 |
Screen Memory | More Than 100, (Dependent on Memory Size) |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | NA MB |
Type Of Battery Used | Lithium Ion Battery pack |
Battery Backup | 08 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 2 Kg, Including Battery. Grams |
Dimensions(LXWXH) | 26.5 X 19.0 X 7.0 cm cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 0 degree to 50 degree C degree celsius |
Operating Humidity | +10 °C ~ +30 °C: 95% RH non-condensing +30 °C ~ +40 °C: 75% RH non-condensing +40 °C ~ +50 °C: 45% RH non-condensing % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | BC430 Power Adapter, International plug adapter set, BP290 (Single capacity Li-ion battery) 28 Wh (8 hours or more), TLS430 Test lead and Alligator clip set ,WC100 color coding clips and regional decals, i430flex-TF, 24 inch (61 cm) length, 4 flexible current probes, 8 GB SD card , PowerLog on CD (includes operator manuals in PDF format) ,USB cable A - Mini B |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | CAT-IV 600V |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 265412365 |
TTC Report Date | 25-October-2017 |
Name Of Lab | FLUKE CORPORATION, USA |
Address Of Lab | USA |
Interface | USB, Wi-Fi, |