The Megger MIT1025 is a 10KV-20T Insulation Resistance tester with test modes IR, IRt, DAR, PI, SV, DD, ramp test with lock test voltage feature. Its dual case design protects the tester from drops/knocks and an inner fire retardant case, short circuit current noise rejection 3mA. Easy rotatory switch for Simple operation and large analogue/digital backlit display for multiple results, operates from battery or AC mains supply. High current, high noise immunity, Voltmeter Function, 5.5 hours logging, PC interface through USB using PowerDB software, rapid charge Li-ion Battery for long working hours with 4.5 hours backup. IP 65 rating with CAT IV 600V to 3000m safety for all applications, GUARD terminal for higher accuracy from leakage current. For more info please refer datasheet of OEM. Warranty One year on main instrument and accessories. Price is inclusive of GST@18percent..
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | Live circuit indicator 30 V to 600v ACDC,50 Hz |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | -20 °C to 50 °C Degree C |
Operating Humidity (RH) | 90% RH non-condensing at 40 °C % |
Power Requirements | Battery Operated |
Type Of Battery | 11.1 V, 5.2Ah Li-ion batteries |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | Power lead, USB cable, PowerDB Lite software, Product information CD, 3 m leadset x 3, large insulated clips |
Dimensions (H X W X L) | L 315 mm x W 285 mm x H 181 mm mm x mm x |
Weight | 4.5KG gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 407 |
Test Report Date | 14-02-2012 |
Name Of The Lab | UKAS-UK |
Warranty | 1 |