01. Portable Dry Chemical Powder ABC type Fire Extinguisher comes fitted with squeeze grip type controllable discharge mechanism to provide flexibility of releasing extinguishing agent on targeted fire location. 02. It contains MAP 90 with 90 Percent concentration of Mono Ammonium Phosphate. 03. The extinguisher is ISI marked, EN PED approved and CE marked. 04. EPDM hose for longer life durability. 05. It has a magnetic Pressure Gauge to enable the checking of pressure gauges correct working without dismantling or opening the cylinder. 06. Vessel used in the manufacturing is constructed using Deep Drawn Technology to keep seamless area not less than 70 Percent of the cylinder, Hydrostatic Pressure Test and Helium Leak Detection Test certification will be provided along with supply. 07. Serial no. and date of manufacturing is embossed on the body of the fire extinguisher..
Other Specifications Download Specification | |
---|---|
Conformity To Standard | IS:15683:2006 With Latest Amdmnt. |
BIS Marking | Yes |
CM/L No. With Validity Period | 8886112 with validity of 31/03/2018 |
Type | Stored Pressure |
Trolley | Without Trolley |
Extinguishing Media | Powder Based |
Foam Based Extinguishing Media | NA |
Powder Based Extinguishing Media | ABC |
Clean Agents Based Extinguishing Media | NA |
Expellant Medium | N2 Based |
Fire Extinguisher Capacity( Foam Based/Water Based) | NA Ltrs |
Powder Based Fire Extinguisher Capacity | 4 Kg |
Carbon Dioxide Based Fire Extinguisher Capacity | NA Kg |
Clean Agents Fire Extinguisher Capacity | NA Kg |
Weight Of Filled Portable Fire Extinghuisher | 6.71 Kg |
Test Pressure For Foam Based/Powder(N≥20) / CO2 Based Fire Extinguisher(N≥35) | 22.16 Bar |
Burst Pressure,Min | 55 Bar |
Discharge Range For Class A Fire Extinguisher(≥2)/Class B (≥1) | 5.97 Meters |
Effective Discharge Time For Fire Extinguisher, Min | 16.15 Seconds |
Fire Rating For Class -A Fire Extinguisher | 2A |
Fire Rating For Class -B Fire Extinguisher | 21B |
Fire Extinguisher Suitable For Class -C Fire | NO |
Fire Extinguisher Suitable For Class -D Fire | NO |
Fire Extinguisher Suitable For Class -K Fire | NO |
Rechargebale | YES |
Color Coding | Red |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | YES |
Test Report No. | a) 110037A, contains MAP 90 ISI marked, EN PED approved and CE marked, Helium Leak Detection Test certification. |
Test Report Date | a) 12/12/2011 |
Name Of The Lab | a) Fire Test & Research Laboratory |
Address Of The Lab | a) Sir Chhotu Ram Bhawan, Sector 32, Gurgaon-122001 Haryana |
Operating Temperature | -30° C to + 55° C ° C |
Fire Extinguisher Suitable For Class -E Fire | YES |