× All the transactions performed on 2.0 is available here. To access Market click "Home".

Digital Milli ohm meter MTQ Micro 3-5 (N and M)(NM-MTQ Micro 3-5)

` 9,999.00

  • MRP: `11500.00

The Digital Milliohm meter is a precision instrument, which is extremely suitable for measurement of low value resistance.The instrument uses state of art technology for measurement of low values of resistances. The measuring technique eliminates errors caused due to resistance in the connecting leads.The instrument uses precision low drift integrated circuits to ensure stability of measurement over widely changing conditions.Micro Ohm Meter Digital Bench 3.5 Dgt., 1 Ohm to 20K Ohm , 7 Ranges.

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection Live circuit indicator 30 V to 600v ACDC,50 Hz
Pass Fail Function Yes
Data Logging more than 99 locations
Software Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range 65 Degree C
Operating Humidity (RH) 85 %
Power Requirements Battery Operated
Type Of Battery 6 AAA Battery
PC Interface Available
Standard Accessories Supplied With The Equipment Yes
Dimensions (H X W X L) 258x115x58 mm x mm x
Weight 5000 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 21454
Test Report Date 21-05-2017
Name Of The Lab Star Labs
Warranty 1

Price Dekho Price Dekho Price List in india