× All the transactions performed on 2.0 is available here. To access Market click "Home".

echo cardiograph machine (branded)(branded 12)

` 142,500.00

  • MRP: `160000.00

12-channel machines, most advanced ECG machines till date,simultaneously acquire and display all 12 leads at any time. BPLs offerings in 12-channel ECGs include Cardiart 9108, Cardioline ar2100view and Cardioline 200, equiped with Glasgow Algorithm.

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 5
  • Functional requirements: electricity (AC-powered) bedside device designed to continuously detect, measure, and display a patient's electrocardiogram (ECG) through leads and sensors attached to the patient, it also typically display heart rate. The device is typically equipped with audible and/or visual alarms that are triggered when the patient's parameters drop below or exceed pre-set limits. Continuous display of patient ECG and heart rate on screen,Allows display of single, 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points.Operator can set audiovisual alarm levels for low or high heart rate.Operates from mains voltage or from internal rechargeable battery. - yes
  • Heart rate measurement range to be at least 30 to 250 bpm, with accuracy better than ± 5 bpm - yes
  • Heart rate trend display of at least previous 24 hours - yes
  • Audiovisual alarms required: high and low heart rate (operator variable settings), cardiac arrhythmia, sensor / wire disconnected, low battery - yes
Other Specifications Download Specification
GMDN Name And Code Multichannel Electrocardiographic , CT-1115
Functional Requirements: Electricity (AC-powered) Bedside Device Designed To Continuously Detect, Measure, And Display A Patient's Electrocardiogram (ECG) Through Leads And Sensors Attached To The Patient, It Also Typically Display Heart Rate. The Device Is Typically Equipped With Audible And/or Visual Alarms That Are Triggered When The Patient's Parameters Drop Below Or Exceed Pre-set Limits. Continuous Display Of Patient ECG And Heart Rate On Screen,Allows Display Of Single, 5 Lead ECG Or Simultaneous Display Of At Least 5 Waves Selected From Up To 12 Points.Operator Can Set Audiovisual Alarm Levels For Low Or High Heart Rate.Operates From Mains Voltage Or From Internal Rechargeable Battery. yes
Heart Rate Measurement Range To Be At Least 30 To 250 Bpm, With Accuracy Better Than ± 5 Bpm yes
Heart Rate Trend Display Of At Least Previous 24 Hours yes
Arrhythmia Detection Facility Required; Minimum Gradation Of 1 Bpm yes
Audiovisual Alarms Required: High And Low Heart Rate (operator Variable Settings), Cardiac Arrhythmia, Sensor / Wire Disconnected, Low Battery yes