HP Tower Server Ml150 Gen9 Xeon E5-2609V4 1.7Ghz / 8-core /20MB /85 W 2P Tower 860121-375Processor Intel Xeon E5-2609V4 / 1.7 Ghz 8 CoreSocket Processor Socket Lga2011-V3Main Features of the Processor TechnologyHyperthreading, Intel Turbo Boost Technology 2Memory Cache 20 Mb L3Cache Per Processor 20 MbMemory RAM 16 Gb Installed / 512 Gb Max. - Ddr4-2400 R Memory , 16 DiMM Slots4LFF 3.5 inch Hot Plug Drive HP H240 12Gb 2-ports Int Smart HBA HP SATA 905 JB Optical HDWRError Correction Ecc Advanced - Pc4-19200Raid Storage Controller Sata 6Gb / S / Sas 12Gb / S -Pcie 3.0 X8 Hp H240 Smart Host Bus AdapterHot Plug - Swap Server Storage Bays 2.5 1 TB SAS Hard Disk Graphic Controller Matrox G200Eh2Gige Network ConnectionPower supply Ca 120/230 V 50/60 Hz2X HP 900W AC 240VDC Power Module Broadcom 5717 Dual port 1GBHP iLO Firmware HPiLO 4Dimensions Width X Depth X Height 20 Cm X 62 Cm X 43.26 CmWeight 16.9 KgWarranty 3 Years.
Other Specifications Download Specification | |
---|---|
Form Factor | Rack |
Processor Make | Intel |
No. Of Slots In Chassis | 16 DiMM Slots |
Blade Server | Without Chassis |
No. Of Blade Server In Chassis | NA |
Max. Number Of Sockets Available On Blade Server | NA |
Max. Number Of Sockets Populated With Processor | NA |
Number Of Core Per Processor | 4 |
Processor Configuration | E3-1585 v5, 4 Core, 3.5 GHz , 8 MB L3 cache memory, 65 watt |
Chipset Compatible With CPU | Yes |
Motherboard (OEMcompatible With CPU) | Yes |
Number Of PCI Slots (Express Gen 3.0 Min.) | NA |
Max Nos Of PCI Lanes | on board Lan |
Memory ( DDR4 RAM Min.) | 16 GB GB |
DDR4 RAM Upgradable Upto (Minimum) | 256 GB GB |
DIMM Slots (Minumum) | 16 No |
Hard Disk Drive Capacity | 1 TB GB |
Hard Disk Drive RPM With SAS (hot Plug Or Better ) | 10000 RPM RPM |
RAID Controller Caches | 512 MB MB |
RAID Controller | 1/5 |
RAID Controller Ports | 4 |
Video Controller (support VGA Or Above Resolution) | Yes |
Keyboard | standard |
Mouse | Optical scroll |
USB Ports | 2 |
Multifunctional Ports (min.) | 4 |
Fiber Channel Ports (min.) | 1 |
Certifications, Compliance & Support By Windows, Red Hat Or Novell. | Yes |
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up | Yes |
FC HBA Dual Port Card | Available |
FC HBA Dual Port Card Speed | HP H240 12Gb |
Chassis Shall Be; 1. Suitable To Accommodate The Blade Servers. 2. Supplied With Interconnect Modules, Power Supplies, Fans & Management Modules. 3. Include All Accessories So That It Can Be Mounted On An Industry Standard 42U Rack. 4. Fully Populated With Power Supplies Redundancy. 5. Supplied With The PDUs To Connect Power Cables To The Chassis Power Input Terminals. 6. Fully Populated With Fans For Cooling With Adequate Redundancy Built In For The Entire Enclosure & Its Components Along With DVD ROM. 7. Complete With Required Number Of Redundant Managed Ethernet Switches To Provide At Least Two Nos. Of Ports Of 10 Gb/s Connectivity. Redundant Fibre Channel Switch To Provide At Least 2 Nos. Of 16 Gb/s Fibre Channel Connectivity To The External SAN Storage. 8. Management Module Which Provides A Single Point Of Control For Intelligent Management Of The Entire Console. It Should Provide Setup & Control Of Enclosure, Should Report Asset And Inventory Information For All The Devices In The Enclosure. It Should Report Thermal & Power Information On Per Server & Per Enclosure Basis And It Should Provide KVM Functionalities & Access For All The Server Blades From The Management Module. | screen blanking , hard disk & system idle mode in power on , set up password , power supply surge protected |
Avaialbility Of List Of Installations During Last 1 Year Along With Peformance Report From The Users Department. | Yes |
Avaialbility Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. | Yes |
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. | Yes |
Test Report No. & Date | na |
Name Of Lab | NA |
Address Of Lab | NA |
BIS Registration Number, Under Compulsory Registration Scheme (CRS) Of Deity | NA |
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. | NA |
Declare Max. Power Consumption Of The System | 900W |
Availability Of Documentary Evidence In Support Of Model Quoted In Commercial Production & Due Evaluation Completed | Yes |
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. | NA |
Server Main Supply | 230V, ±10%,50 Hz |
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) | Yes |
RoHS Compliance | Yes |
Warranty | 3 |