The Ceasefire Water Mist and CAF Fire Fighting System Bike Mounted type low pressure design comes fitted with following -01. Two low pressure design watermist backpack type fire extinguishers with spare air cylinder.02. Rating of 55A, 233B and 1000V with standard AFFF Foam confirming to UL 162 standard.03. The motor cycle mounting kit includes a windshield, a hooter, two blinking lights, a first aid box and fixtures to add space to store two air cylinders.04. The low pressure design watermist backpacks are an EN PED approved and CE Marked.05. The discharge gun nozzle has a special feature of dual mode, It changes from Jet to Spray mode with a simple twist in a second and vice versa.06. Ceasefire low pressure design watermist backpack is tested and certified by ERDA for non conductivity as per Cl. No. 8.6 of IS 15683-2006 and Cl. No. 9 of EN 3-7-2004..
Other Specifications Download Specification | |
---|---|
Conformity To EN Standards | Yes |
Cylinder Capacity | 4.7 Ltrs |
Mounting Type | Motorcycle Mount |
Configuration (Two Backpacks Each Containing Two Air Cylinder Of 4.7 Litre Each Shall Be Mounted On The Motorcyle Royal Enfiled Electra 5 Speed 350 Cc. Also Mounted On Motorcyle Shall Be Front Windshield ( 2mm Thick FRP), Leg Guard (made From 25mm Dia 16 Gauge Nickel Plated Steel Pipe), A Siren (12V 30 Amp Audible At A Distance Of 200m), Two Blinking Lights (12V 20W Each Red Lights With Flasher), First Aid Box (cotton Absorbant 100g, Band Aid 10 Pcs, Burnol 2 Pcs, Tincture Iodine 100 Ml) And Gel Blanket. The Motor Cycle Shall Have Space To Store Two Air Cylinders And Breathing Apparatus. The Wind Shield Shall Be Duly Markedwith A Logo As Desired By The User. Note: Motor Cycle Is Not In The Scope Of Supply To Be Purchased By Buyer Separately.) | Yes |
Pressure | 8 Bar |
Type Of Foam | Standard Foam as per UL 162 or IS 4989 Standards |
If Special Foam Mention The Compostion For Special ,otherwise Put NA | NA |
Commercial Brand Name Of The Special Foam (fire Extinguishing Medium) As Per Accredited Laboratory Test Report Where In Fire Rating Has Been Achieved, To Be Declared. | NA |
Spreading Coefficient For Standard AFFF Compound Shall Be +3 Minimum | Yes |
Spreading Coefficient For Special AFFF Compound Shall Be +5 Minimum | Yes |
The Concentration Of The Compound Shall Be Nominal 6% | Yes |
Extinguishing Medium | Water Mist & CAF |
Extinguishing Gun Material | Stainless Steel |
If Others Mentions The Material For Extinguishing Gun,otherwise Put NA | NA |
Extinguishing Gun Weight | 1620 grams |
Pressure Vessel Material | Stainless Steel |
Pressure Vessel Capacity | 9 Ltrs |
Compressed Air Cylinder Capacity At 300 Bar | 4.7 Ltrs |
Pressure Gauge To Monitor Air Cylinder Pressure | Yes |
Fire Rating | 27 A, 233B, 1000V with Standard AFFF Compound conforming to UL-162 |
Compressed Air Cylinder Material | Carbon Composite |
"Length Of Hose " | 1.3 meters |
The Air Hoses Shall Be Suitable For Minus 40 Deg C To 100 Deg C Temperatures | Yes |
Minimum Lancing Distance Of Gun | 13.2 meters |
Flow Rate( Must Be In Between 0.42 To 0.45) | 0.42 ltr/sec |
Operating Time In Full Throttle( Must Be In Between 20 To 23) | 21.66 seconds |
Weight Of Fully Charged System (#) | 26.186 kg |
Main Components: Pressure Vessel To Hold The Media With Safety Valve, Compressed Air Cylinder Couped With A Reducer, Hose Pipes For Discharge Of Wter Mist Media, Extingushing Gun | Yes |
System Shall Be Designed For Maximum Operating Temperature TSmax And Minimum Operating Temperature TSmin Of 60 Deg C Or More And 5 Deg C Or Less Respectively And Certified By The Manufacturer Accordingly | Yes |
Two Nos. Of Back Pack Type Fire Extinguishers For Motor Cycle Mounted | Yes |
"The Air Cylinders Shall Have PESO, Nagpur Approval " | Yes |
Availability Of Test Report From NABL/ILAC/Central Govt. Lab To EN Standard | Yes |
Test Certificate No. | a) 130248, b) 130248-A, c) 163, d) 4160032, e) HIMP/09/1746-1, Rating of 55A, 233B and 1000V with standard AFFF Foam confirming to UL 162 standard, EN PED approved and CE Marked. |
Test Report Date | a) 19/03/2014, b) 21/03/2014, c) 15/02/2016, d) 25/01/2016, e) 17/03/2011 |
Name Of Lab Where Test Conducted | a) and b) Fire Test & Research Laboratory c) Advance Firetec and Research Lab. Pvt. Ltd. d) National Test House e) Electrical Research and Development Association |