Floating measurements of high voltages are very common in industrial electronics and electrical testing. Single phase and Three phase measurements on Oscilloscope need completely isolated inputs. Scientech 824A PowerScope is an ideal instrument for such applications. With X100 attenuation signals up to 1500Vpp can be measured. Scientech 824A PowerScope is very useful for testing UPS, induction furnace, electric control systems, motors, transformers etc.The built-in Ramp Pedestal firing circuit provide gate pulse for SCR to conduct experiments in power electronics.Its firing angle can also be changed. Ready to use built-in DC and AC Power Supplies are very useful in circuittesting..
Other Specifications Download Specification | |
---|---|
Type | Analog |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 2 Number |
Digital Channels | Yes |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | Not Applicable GS/sec GS/sec |
Sampling Rate Per Digital Channel Simultaneously | Not Applicable Mega Points Mega Points |
Min. Detectable Pulse Width | Not Applicable ns ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | No |
Vertical Sensitivity | 2mV/Div to 5 V/Div |
Vertical Resolution | NA bits |
Coupling | AC, DC and Ground |
Time Base Range | Time coefficients : Microcontroller based 18 calibrated steps, 0.5 μs/div.-0.2s/div. (1-2-5 sequence). Electronic control, Display on LCD |
Trigger Types | Auto / Level |
Measurements | 40 MHz |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | Yes |
Acquisition Modes | +/-10% |
Display Type | Colour |
Display Size | 8X10 CM CM |
I/O Interface | USB |
Standard Accessories To Be Supplied | Included Accessories : BNC-Test prod cable - 1 no. BNC - Crocodile cable - 1 no. Test Prod - 1set Power cord - 1 no. BNC to BNC (small) - 2 nos |
Operating Temperature Range | 0-40 CENTIGRADE Degree C |
Operating Humidity (RH) | 80%R H % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | NSICGPIND20140009211 |
Test Report Date | 10.06.2016 |
Name Of The Lab | NSIC Indore |
Warranty | 1 Year |
Real Time Bandwidth | 30 MHz |
Record Length Per Analog Channel Simultaneously | Not Applicable GS/sec Mega Point |
Sample Rate Per Analog Channel Simultaneously | Not Applicable Mega Points GS/sec |
Waveform Update Rate | Not Applicable Waveforms Waveforms/ |
Time Base Accuracy | 3 PPM |