microwave signal sensor (divisus)(cvd 107)

` 210,390.46

  • MRP: `252468.55

Microwave signal sensor detect and analysed the change in microwave signal.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Display Type - 24 GHz
  • Capture/Demodulation Bandwidth (Max.) - 25 MHz
  • I/Q memory Depth (256 MB) - Yes
  • Traces Types - Normal (RMS), Average, Max. Hold, Min. Hold
  • Measurement Range (DANL to Max. Safe input Level) - 24 GHz dBm/Hz - dBm
Other Specifications Download Specification
Frequency Range 20Hz - 26.5 GHz
Display Type 24 GHz
Capture/Demodulation Bandwidth (Max.) 25 MHz
I/Q Memory Depth (256 MB) Yes
Trigger Free Run, Power Trigger, External
Traces Types Normal (RMS), Average, Max. Hold, Min. Hold
Sample Rate 100 Ms/s
Ref. Frequency Aging (1 X 10 ^ -7) 24.123
Measurement Range (DANL To Max. Safe Input Level) 24 GHz dBm/Hz - dBm
Max. Safe Input Level (Should Be Less Than Or Equal To +30 DBm ) Yes
Displayed Average Noise Level ( 10 MHz To 3/6/13/26.5 GHz, DANL Should Be Less Than Or Equal To -130 DBm/Hz ) Yes
Modulation Analysis AM, FM, PM, BPSK, QPSK, Pi/4 DQPSK, 8PSK, 16SQAM, 32QAM, 64QAM, 128QAM, 256QAM, GMSK,GFSK
"Multi Domain Analysis With Stand Alone Software" Time, Frequency, Modulation, Spectrogram
Automatic Measurement (Time Mode) IQ vs Time, Power vs Time, Frequency vs Time, CCDF, crest factor, Pulse Measurements: Pulse Width, Pulse Peak Power, On/Off Ratio, Pulse Ripple, Pulse Repetition Interval, Duty Cycle Pulse-Pulse, Phase, Channel Power, Occupied BW, Frequency Deviation
Interface USB, LAN/GPIB
Operating Temperature 5 to 40 degree C and 80 % RH at 40 degree C
Power Requirements (230 +/- 10% VAC, 50 Hz) Yes
Rack Mount Kit For Signal Analyzer Yes
Availability Of The Test Report From Central Govt./ NABL/ ILAC Accredited Lab As Per Doc Correction Slip No. 38 Dtd 18/1/12 To Be Read In Conjunction With P&C Circular No. 71 Dtd 29/10/14 For Each Model Of Signal Analyzer. Yes
TTC No. & Date 2603953
Name Of The Lab Osnova Bezopasnosti LLC
Address Of The Lab Russia, Stavropol, 355000, ul. Vasilkovaya 29.
Type Test Reports Shall Consist Of Verification Of All The Features & Functional Parameters & Environmental Tests. Yes
Dry Heat Test: For 16 Hrs At A Temp. Of 55 Degree C In Accordance With IS: 9000/part-3/section-5/1977 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
Cold Test: For 4 Hrs At A Temp. Of (-)10 Degree C In Accordance With IS: 9000/part-2/section-4/1977(reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
Damp Heat Test: For 2 Cycles Of 24 Hrs (12 + 12h) Each At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
The Scope Of Supply Shall Include One Set Of Operation And Maintenance Manual For Each Equipment. Yes