Fluke 190-102 /S Measurements - V dc, V ac rms, V ac plus dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac plus dc, frequency in Hz, rise time using cursors, fall time using cursors, Power Factor PF, Watts, VA, VA reactive, phase between any 2 inputs, pulse width pos./neg., duty cycle pos./neg., temperature C, temperature F not for Japan, dBV, dBm into 50 I and 600 I, VPWM ac and VPWMac plus dc for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ration 190-xx2 only, FFT, One mathematical operation on any 2 input channels add/subtract/multiply X-Y-mode Frequency Spectrum using FFT analysis. Display Size - 127 mm x 88 mm 153 mm/6.0 in diagonal LCD, Vertical Sensitivity 2 mV/div to 100 V/div, plus variable attenuation , Time Base AccuracyPPM - Plus minus 0.01 percent of reading plus 1 pixel, Frequency Spectrum using FFT analysis , Power Supply -Mains adapter/battery charger BC190 included, version depending of country WITH 3 YEARS WARRANTY..
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Non -Windows |
Bandwidth Upgradability | Yes |
No. Of Analog Channels | 2 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | 8 ns peak detect on each channel ns ns |
Memory Upgradability | Yes |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 2mV/Div to 5 V/Div |
Vertical Resolution | 8 bits |
Coupling | AC or DC, with ground level indicator |
Time Base Range | "5 ns/div to 4 s/div" |
Trigger Types | "Automatic Connect-and-View™, free run, single shot, edge, delay, dual slope, video, video line, selectable pulsewidth (channel A only), N-cycle" |
Measurements | Yes it will be provided and details are given in product description |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | No |
In-built Function Generator | No |
Acquisition Modes | "Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay" |
Display Type | Colour |
Display Size | 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD CM CM |
I/O Interface | USB and Pendrive |
Standard Accessories To Be Supplied | "BP290 (2400 mAh), VPS410-x (one red, one blue), TL175 (one red, one black) with test pins, Battery charger (BC190), Hangstrap, Handstrip (user selectable for left- or right hand use), Multi-language users manuals on CD-ROM, FlukeView® demo package (with restricted functionality), and USB interface cable for PC connectivity" |
Operating Temperature Range | 0 °C ~ +40 °C; 0 °C ~ +50 °C excluding battery Degree C Degree C |
Operating Humidity (RH) | " +10 °C ~ +30 °C: 95 % RH non-condensing +30 °C ~ +40 °C: 75 % RH non-condensing +40 °C ~ +50 °C: 45 % RH non-condensing" % % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | A78110 |
Test Report Date | 24/11/2017 |
Name Of The Lab | Fluke (ISO/IEC 17025:2005) approve Lab |
Warranty | 3 Year |
Real Time Bandwidth | 100 MHz |
Record Length Per Analog Channel Simultaneously | "10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord™ Roll mode" Mega Point Mega Point |
Sample Rate Per Analog Channel Simultaneously | "1.25 GS/s for each channel" GS/sec GS/sec |
Waveform Update Rate | Available Waveforms/ Waveforms/ |
Time Base Accuracy | 0.05 PPM |