01. Portable Dry Chemical powder ABC type Fire Extinguisher comes fitted squeeze grip type controllable discharge mechanism to prove flexibility of releasing extinguishing agent on targeted fire location. 02. It contains MAP 90 with 90 percent concentration of Mono Ammonium Phosphate. 03. The extinguisher is ISI marked. 04. The extinguisher is ISI approved and tested as per IS standard. 05. EPDM Hose for longer life and durability. 06. It has a magnetic pressure gauge to enable the checking of pressure gauges correct working without dismantling or opening the cylinder. 07. Vessel used in the manufacturing is constructed using Deep Drawn Technology to keep seamless area not less than 70 percent of the cylinder, Hydro-static pressure test and helium leak detection test certification will be provided along with supply. 08. Serial no. and date of manufacturing is embosses on the body of the fire extinguisher..
Other Specifications Download Specification | |
---|---|
Conformity To Standard | IS:15683:2006 With Latest Amdmnt. |
BIS Marking | Yes |
CM/L No. With Validity Period | 2899592 with validity of 22/07/2018 |
Type | Stored Pressure |
Trolley | Without Trolley |
Extinguishing Media | Powder Based |
Foam Based Extinguishing Media | NA |
Powder Based Extinguishing Media | ABC |
Clean Agents Based Extinguishing Media | NA |
Expellant Medium | N2 Based |
Fire Extinguisher Capacity( Foam Based/Water Based) | NA Ltrs |
Powder Based Fire Extinguisher Capacity | 6 Kg |
Carbon Dioxide Based Fire Extinguisher Capacity | NA Kg |
Clean Agents Fire Extinguisher Capacity | NA Kg |
Weight Of Filled Portable Fire Extinghuisher | 8.80 Kg |
Test Pressure For Foam Based/Powder(N≥20) / CO2 Based Fire Extinguisher(N≥35) | 22.88 Bar |
Burst Pressure,Min | 55 Bar |
Discharge Range For Class A Fire Extinguisher(≥2)/Class B (≥1) | 4 Meters |
Effective Discharge Time For Fire Extinguisher, Min | 12.75 Seconds |
Fire Rating For Class -A Fire Extinguisher | 3A |
Fire Rating For Class -B Fire Extinguisher | 21B |
Fire Extinguisher Suitable For Class -C Fire | YES |
Fire Extinguisher Suitable For Class -D Fire | NO |
Fire Extinguisher Suitable For Class -K Fire | NO |
Rechargebale | YES |
Color Coding | Red |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | YES |
Test Report No. | 130530 ( As per IS 15683, Portable Fire Extinguisher DCP ABC Stored pressure type, 6 KG |
Test Report Date | 06/07/2017 |
Name Of The Lab | Fire test & Research Laboratory |
Address Of The Lab | V & PO Rattangarh, 9th Millstone, Gohana, State Highway 11, Sonipat,Haryana- 131 001 |
Operating Temperature | -30° C to + 55° C ° C |
Fire Extinguisher Suitable For Class -E Fire | NO |