× All the transactions performed on 2.0 is available here. To access Market click "Home".

Coolant Filtration Machine 1000 LPH (Alfa Next Gen)(ANGS-COOL-1000)

` 279,720.00

  • MRP: `310800.00

Coolant filtration machine with flow rate of 1000.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Type - Portable
  • Type of Oil for which machine is to be used for cleaning - Others
  • Type of Cleaning - Removal of Solid Contamination Only
  • Centrifuge Pump Flow Rate - NOT REQUIRED LPM
  • Suction Pump Flow Rate - NOT REQUIRED LPM
Other Specifications Download Specification
Mode Of Working Offline
Type Portable
Type Of Oil For Which Machine Is To Be Used For Cleaning Others
Type Of Cleaning Removal of Solid Contamination Only
Nominal Flow Rate 1000 LPH
Centrifuge Pump Flow Rate NOT REQUIRED LPM
Centrifuge Motor Capacity 0.5 HP
Centrifuge Make Of Motor others Confirming to IS 325:1996 reaffirmed 2007 with ISI Marked
Suction Pump Flow Rate NOT REQUIRED LPM
Suction Pump Motor Capacity 0.5 HP
Make Of Motor(Suction Pump) others Confirming to IS 325:1996 reaffirmed 2007 with ISI Marked
Discharge Pump Flow Rate 20 LPM
Discharge Pump Motor Capacity 0.5 HP
Make Of Motor( Discharge Pump) others Confirming to IS 325:1996 reaffirmed 2007 with ISI Marked
Dirt Holding Capacity others grams
Dirt Holding Capacity( For Others) 5000 grams
Minimum Size Of Dirt( Including Metallic ,Non Metallic ,Suspended Soild Particle ) upto 10 micron
Length Of Inlet Wire Braided Hose Pipe 5000 mm
Diameter Of Inlet Wire Braided Hose Pipe 60 mm
Length Of Outlet Wire Braided Hose Pipe 5000 mm
Diameter Of Outlet Wire Braided Hose Pipe 20 mm
Vacuum Pump For First Stage No
Vacuum Pump For Second Stage No
Vacuum Pump Motor Capacity ( For First Stage ) NA HP
Vacuum Pump Motor Capacity ( For Second Stage ) NA HP
Vacuum Booster For First Stage No
Vacuum Booster For Second Stage No
Vacuum Booster Motor Capacity ( For First Stage ) NA HP
Vacuum Booster Motor Capacity ( For Second Stage ) NA HP
Vacuum Blower Yes
Vacuum Blower Motor Capacity 2 hp
Moisture Separator No
If Yes Then Moisture Separating Capacity (otherwise Put NA) NA ml
Moisture Seperator Capacity (for Others ) NA ml
Operating Pressure ,Max 2 Bar
Operating Temperature NA Degree Celcius
Heating System Yes
Heater Capacity NOT REQUIRED kw
Degassing Chamber Yes
Dimensions Of Degassing Chamber (Diameter X Height) NOT REQUIRED mm x mm
Capacity Of Degassing Chamber NOT REQUIRED ltrs
Ionic Reaction Cartridge No
Oil Reclamation Cartridge No
Water Adsorption Cartridge No
Filter Cartridge ( For Solid Contamination Removal Only) Non Consumable
Magnetic Strainer No
Length Of The Centrifugal Oil Cleaning Machine 1100 apx. mm
Width Of The CentrifugalOil Cleaning Machine 600 apx. mm
Height Of The Centrifugal Oil Cleaning Machine 900 apx. mm
Weight Of The Centrifugal Oil Cleaning Machine 900 apx. Kg
Make Of Control Panel (All Parts) Others Confirming to IS
Dimensions Of Panel Box Confirming To IS 10322/1982Reaffirmed 2005( Length X Width X Height ) others mm x mm x mm
If Others Then Specify The Dimensions In LxWx H) 500X300X550 apx. mm x mm x mm
Thickness Of Panel Box Confirming To IS 10322/1982Reaffirmed 2005 300 apx. mm
Online Moisture PPM Sensor No
Tramp Oil Skimmer Yes
Flowmeter Yes
Voltmeter (0-500 V) With Inbuilt Selector Switch Yes
Control Transformer Yes
Ammeter Digital 0-20 Amps Yes
Hours Counter Meter Yes
Indicator Light 3-ph Yes
No. Of Push Button 4
Legent Plate 3mm Thick Yes
MCB TP 10-32 Amp Yes
MCB SP 2- Amp For Volt/Cont Yes
12 Amp Contactor 3 Pole Yes
O/L Relay 4-6.5 Amp Yes
Terminal Block 2.5 Mm Yes
Protection Relay Model -VSP-D1 Yes
Over Load Trip Indication 22.5 Mm Dia Yes
PVC Gland 13.5 /16x4x1.5 Mm Yes
Cable 4Cx 1.5 Mm(5 Meter) Yes
Machine Enclosure Open Type
Machine Wheels Castor
Lsit Of Standards Accessories Of Panel Box With Numbers To Be Provided Indicator Light 3 phase - 3 Nos. Volt meter - 1 Nos. Amp. meter - 1 Nos. Hour Counter - 1 Nos. Push Button - 4 Nos. MCB TP 32 Amp - 1 Nos. MCB SP 6 Amp - 3 Nos. Contractor - 12 Amp 3 pole 2 Nos. O/L Relay - 2.5-4 Amp - 2 Nos. Protection relay - VSP- D-1 Cable Wire - 4C X 1.5mm2
Availability Of Test Report From Central Govt./NABL/ILAC Acredited Lab To Prove Confirmity To Specification Yes
Test Report No. S-2498
Test Report Date 3-Jan-2016
Name Of The Lab Narang Metallurgical and Spectro Services
Address Of The Lab Delhi

Price Dekho Price Dekho Price List in india