× All the transactions performed on 2.0 is available here. To access Market click "Home".

pulse oxymeter table top with nibp adult or pediatric (scure)(ttpon-01)

` 34,990.00

  • MRP: `40000.00

Pulse Oxymeter, line PoweredA mains electricity AC-powered photoelectric device intended for the continuous transcutaneous measurement and display of haemoglobin oxygen saturation SpO2. The signals, typically produced by light-emitting diodes LEDs and a receiving detector in a probe, or directly built-in, are used to make the measurements using the principle of spectrophotometry. The oximeter displays the SpO2 values and may calculate / display other parameters, e.g., pulse rate, electrocardiogram ECG. The device is typically used at the bedside. - yesSpO2 measurement range at least 40-70 and 70 to 99 , minimum gradation 1 - yesAccuracy of SpO2 better than 1 for range 40-70 and better than 3 for range 70-99. - yesAccuracy of pulse rate better than 5 bpm - yesDisplay type - TFT Screen.

  • Availability: 45 In Stock
  • Min. Qty. Per Consignee: 1
  • "Pulse Oxymeter, line Powered:A mains electricity (AC-powered) photoelectric device intended for the continuous transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2). The signals, typically produced by light-emitting diodes (LEDs) and a receiving detector in a probe, or directly built-in, are used to make the measurements using the principle of spectrophotometry. The oximeter displays the SpO2 values and may calculate / display other parameters, e.g., pulse rate, electrocardiogram (ECG). The device is typically used at the bedside." - yes
  • SpO2 measurement range at least 40-70 and 70 to 99 %, minimum gradation 1% - yes
  • Accuracy of SpO2 better than ± 1% for range 40-70 and better than ± 3% for range 70-99. - yes
  • Accuracy of pulse rate better than ± 5 bpm - yes
  • Display type - TFT Screen
Other Specifications Download Specification
GMDN Name And Code Pulse oximeter CT 1446
"Pulse Oxymeter, Line Powered:A Mains Electricity (AC-powered) Photoelectric Device Intended For The Continuous Transcutaneous Measurement And Display Of Haemoglobin Oxygen Saturation (SpO2). The Signals, Typically Produced By Light-emitting Diodes (LEDs) And A Receiving Detector In A Probe, Or Directly Built-in, Are Used To Make The Measurements Using The Principle Of Spectrophotometry. The Oximeter Displays The SpO2 Values And May Calculate / Display Other Parameters, E.g., Pulse Rate, Electrocardiogram (ECG). The Device Is Typically Used At The Bedside." yes
SpO2 Measurement Range At Least 40-70 And 70 To 99 %, Minimum Gradation 1% yes
Accuracy Of SpO2 Better Than ± 1% For Range 40-70 And Better Than ± 3% For Range 70-99. yes
Pulse Rate Range At Least 30 To 240 Bpm, Minimum Gradation 1 Bpm yes
Accuracy Of Pulse Rate Better Than ± 5 Bpm yes
Signal Strength Or Quality To Be Visually Displayed yes
Audiovisual Alarms Required: High And Low SpO2 And Pulse Rate (operator Variable Settings), Sensor Disconnected,sensor Failure, Low Battery yes
Display Type TFT Screen
Memory Minimum 24 hrs trend memory for SpO2 & PR
User's Interface Easily accessible touch button to operate the machine
Inbuilt Software And/or Standard Of Communication yes
Weight 1500 gram
Mobility, Portability Protective splashproof case for clean storage and safe transport
Display Must Allow Easy Viewing In All Ambient Light Levels yes
Noise Lavel 45 dba
Heat Dissipiation: Should Maitain Nominal Temp And The Heat Should Be Disbursed Through A Exhaust Cooling Fan yes
Power Input And Frequency 220 to 240V, 50 Hz
Power Consumption 220 to 240v, 50hz Watt
Power Cable Length 3 meter
Electrical Protection Provided By Fuses In Both Live And Neutral Supply Lines. yes
"Operating Condition:Capable Of Operating Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90% In Ideal Circumstances. Circumstances" yes
"STANDARDS AND SAFETY:Should Be FDA / CE Approved Product ISO 80601-2-61-2011: Medical Electrical Equipment- Part 2-61: Particular Requirements For The Basic Safety Snd Essential Performance Of Pulse Oxymeter. Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1, EMC Safety Confirms To IEC 60601-1-2 Standard Requirement; Manufacturer / Supplier Should Have ISO 13485 Certificate For Quality Standard Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1 Shall Meet IEC-60601-1-2 (General Requirements For Safety - Electromagnetic Compatibility) And IEC 60601-2-25 (essential Performance Of Electrocardiographs)" yes
Warranty 3 years warranty & one year with min. 3 free servicing.
Others: List Of Important Spare Parts And Accessories With Their Part Number And Costing. Certificate Of Callibration And Inspection To Be Provided yes

Price Dekho Price Dekho Price List in india