× All the transactions performed on 2.0 is available here. To access Market click "Home".

1.0 KVA ONLINE UPS 1 KVA ON LINE UPS WITH ISOLATION TRANSFORMER 240 MINUTES BACKUP TIME INDICATIVE (harsh)(1kva 240 minutes back up time on line ups ONLINE UPS 3 or 1000VA ONLINE UPS)

` 199,000.00

  • MRP: `259000.00

Online UPS with Isolation Transformer , heavy duty copper wound , for single phase Output and Input voltage , with Minutes backup time , ISO 9001 ,2015 and Iso 14001,2015 , CE certificate , BATTERY WARRANTY AS PER BATTERY MANUFACTURER TWO YEARS ON SMF, we also take AMC OF ONLINE UPS.

  • Availability: 50 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 6400 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 1 KVA
Technology IGBT-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 240 Minutes
Minimum VAH 6400 VAH
Voltage Regulation From No Load To Full Load 0.2 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 0.5 %
Overall Efficiency 95 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. R-81001295
Type Test Certificate Date JAN 2017
Name Of Lab OWN
Address Of Lab DELHI
Supply & Commissioning AS PER REQUIREMENT
Warranty 3 Years

Price Dekho Price Dekho Price List in india