Film format min. 10 x 10 cm 4 x 4,max. 45 x cm 173/4 xFilm typesheet and rollfilmsProcess time-1 5 min 60 300 secCapacity at 60 sec process timeFilm format L x W in cm 10 x 10 4 x 4 4 x parallel 3020 films/hFilm format L x W in cm 24 x 30 91/2 x 12 348 films/hFilm format L x W in cm 35 x 43 14 x 17 245 films/h Developer temperature 28 40 C 82 104 F Dryer temperature 35 70 C 95 158 FFilm detection 4 sensors infrared Replenishment rates 150 3000 ml/m2 ml per 10 square feet Replenishment containers 25 l 6.6 galAnti-oxidation selectable, off or 5 99 min intervalsAnti-cristallisation 20 min intervalsProgram memory5 programs Tank volumes D/F/W12.5/12/13 Litre 31/4/3/31/2 gallonsWater consumption1.9 l/min 1/2 gal/min during processing 0.0 l/min 0.0 gal/min during stand-byEnergy consumption 2.5 kWh during processing 0.23 kWh during stand-by Dimensions L/W/H 97 x 68 x 127 cm 38 x.
Other Specifications Download Specification | |
---|---|
Table Top Automatic Medical X Ray Film Processor Machine | Yes |
The Assembly Made Up Of Material Non Corrosive | Yes |
Length Of Machine | 97 cm |
Width Of Machine | 68 cm |
Height Of Machine | 127 cm |
Weight (Empty) | 91 kg |
Auto Developer , | Yes |
Auto Fixer | Yes |
Auto Washer | Yes |
Auto Dryer | Yes |
Material Of Cabinet | ABS Plastic |
Rollers Mechanism | Motrised |
Rollers Material | PVC with inner pipes of SS-304 Grade |
Minimum Film Size Length X Width | 100 x 100 |
Maximum Film Size Length X Width | 356 x 432 |
Continious Film Roller Transport And Auto Start And Stop Facility | Rigid PVC |
Processing Time: 90 Sec To 200 Sec In Steps Of Six Second With LED Display | Yes |
Processing Capacity Of Size 356mm X 432 Mm In 90 Second Mode | Yes |
Minimum Capacity Of Fixer,Washer And Developer Tank | 5 |
Mimimum Capacity Of Replenishment Developer And Fixer Tank With Overflow Drain Facility | 25 |
Automatic Replenishment | Yes |
Developer And Fixer Temprature Adjustable Throught Automatic Temprature Controller | Yes |
Operating Temp Range | (28-37 )degree degree |
Dryer Temprature(maximum) | 70 degree |
Power Supply | 230 volt A.C |
Maximum Power Consumption | 1.4 kwh |
Water Filter Compatible With Equipment Supplied With Equipment | Yes |
Manual ,auto Stop With Power Saver/standby Mode Facility | Yes |
High Voltage Test 1.5 KV For I Minute | Yes |
Minimum Insulation At 500 V DC | NA |
Instruction Manual Supplied With Equipment | free |
Chemicals/Materail For Running Equipment For Minimum One Month | 30 days |
Radiology Certificate For Processed Film | yes |
Availibility Of Type Test Report For Performance Test | yes |
Test Report To Shown To Buyer As And When Required | Yes |
Test Report Number & Date | K091628-12.08.2009 |
Name & Address Of Laboratory | DEPARTMENT OF HEALTH & HUMAN SERVICES |
Certifiacation | European-CE,US-FDA ISO:13485 |