× All the transactions performed on 2.0 is available here. To access Market click "Home".

anemometer (standard)(anemometer)

` 6,999.00

  • MRP: `9999.00

LCD Digital Anemometer Air Wind Speed Scale Gauge Meter Thermometer, 1. Measure wind speed and temperature 2. The wind speed measuring range is from 0 to 30m/s 3. Current and average wind speed measuring 4. Maximum and minimum wind speed measuring.

  • Availability: 4 In Stock
  • Min. Qty. Per Consignee: 1
  • Display type - LCD Backlit
  • Display Mode - lcd
  • Number of Current Channels - 1 Nos.
  • Facility to Measure RMS Voltage - Available
  • Measurable voltage resolution - 12 Volts
Other Specifications Download Specification
Type Of Power Analyzer Single phase
Display Type LCD Backlit
Display Mode lcd
Number Of Current Channels 1 Nos.
Number Of Voltage Channels 12 Nos.
Facility To Measure RMS Voltage Available
Measurable Voltage Range 12 Volts
Measurable Voltage Accuracy + - 1%
Measurable Voltage Resolution 12 Volts
Facility To Measure RMS Current Available
Measurable Current Range 2 Ampere
Measurable Current Accuracy + - 1%
Measurable Current Resolution 1 Ampere
Facility To Measure Active, Reactive And Apparent Power Available
Maximum Power That Can Be Measured .001 KW
Power Accuracy = 2 %
Power Resolution 2 Watt
Facility To Measure Active, Reactive And Apparent Energy Available
Facility To Measure Sag(dips) And Swell(surge) Available
Facility To Measure Frequency Available
Frequency Range That Can Be Measured 50 Hz
Facility To Measure Total Harmonic Distortion Available
Accuracy In Measurement Of Total Harmonics Distortion NIL
Resolution In Measurement Of Total Harmonics Distortion NIL
Facility To Measure Inter Harmonics Available
Order(n) To Which Facility To Measure Harmonics Available NIL
Facility To Measure Power Factor Available
Accuracy In Measurement Of Power Factor .6
Facility To Measure Distortion Factor Available
Accuracy In Measurement Of Distortion Factor .4
Facility To Measure Ripple Factor Available
Accuracy In Measurement Of Ripple Factor 4
Facility To Measure Voltage And Current Unbalance Available
Facility To Measure Inrush Current Available
Facility To Measure Flicker Available
Facility To Measure Crest Factor Available
Measurable Crest Factor Range 2-5
Measurable Crest Factor Accuracy .1 %
Measurable Crest Factor Resolution 2 TO 4
Screen Memory 2 shots
Data Transfer Software Provided For Analysis On PC Yes
Internal Memory .5 MB
Type Of Battery Used 12 v
Battery Backup 3 Hours
Power Supply(volts In AC) 230
Weight Of The Analyser 340 Grams
Dimensions(LXWXH) 6X3X5 cmXcmXcm
Provision For External SD Card Yes
Operating Temperature Range 2-4 degree celsius
Operating Humidity 50% %
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer set
Compliance To IEC 61000-4-30 Yes
Category Of Safety Rating CAT-VI
Dry Heat Test As Per IS :9000(Part 3/Section 5) Yes
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) Yes
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) Yes
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. Yes
Type Test Report No. 85/5
TTC Report Date 28.6.13
Name Of Lab erdc
Address Of Lab delhi
Interface standard

Price Dekho Price Dekho Price List in india