× All the transactions performed on 2.0 is available here. To access Market click "Home".

wireless signal analyzer warp (mango)(warp)

` 1,874,999.00

  • MRP: `1550000.00

Wireless Signal Analyzer is a Wireless Open-Access Research Platform WARP. A Salable And Extensible Programmable Wireless Platform, Built From The Ground Up To Prototype Advanced Wireless Networks. WARP Combines High-Performance Programmable Hardware With An Open-Source Repository Of Reference Designs And Support Materials.The Project Has Since Grown Into A Self-Sustaining Open-Source Effort With Users Around The World. Mango Communications Spun Off From The Rice WARP Project In 2008 With The Initial Goal Of Manufacturing And Distributing The Rice WARP Hardware. In 2012 Mango Released The Entirely Re-Designed WARP V3 Hardware. Today Mango Engineers Are The Most Active Contributors To The WARP Repositoryand Forums, Providing Ongoing Development And Support Of Open-Source WARP Designs, Including WARPLab 7 And The 802.11 Reference Design.You Can Buy WARP Hardware Under Special University Discount And Be A Part Of WARP Forum ..

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Display Type - 10-Inch TFT Fingre-touch
  • Capture/Demodulation Bandwidth (Max.) - 25 MHz
  • I/Q memory Depth (256 MB) - Yes
  • Traces Types - Normal (RMS), Average, Max. Hold, Min. Hold
  • Measurement Range (DANL to Max. Safe input Level) - 10K dBm/Hz - dBm
Other Specifications Download Specification
Frequency Range 20Hz - 3 GHz
Display Type 10-Inch TFT Fingre-touch
Capture/Demodulation Bandwidth (Max.) 25 MHz
I/Q Memory Depth (256 MB) Yes
Trigger Free Run, Power Trigger, External
Traces Types Normal (RMS), Average, Max. Hold, Min. Hold
Sample Rate 100 Ms/s
Ref. Frequency Aging (1 X 10 ^ -7) 108
Measurement Range (DANL To Max. Safe Input Level) 10K dBm/Hz - dBm
Max. Safe Input Level (Should Be Less Than Or Equal To +30 DBm ) Yes
Displayed Average Noise Level ( 10 MHz To 3/6/13/26.5 GHz, DANL Should Be Less Than Or Equal To -130 DBm/Hz ) Yes
Modulation Analysis AM, FM, PM, BPSK, QPSK, Pi/4 DQPSK, 8PSK, 16SQAM, 32QAM, 64QAM, 128QAM, 256QAM, GMSK,GFSK
"Multi Domain Analysis With Stand Alone Software" Time, Frequency, Modulation, Spectrogram
Automatic Measurement (Time Mode) IQ vs Time, Power vs Time, Frequency vs Time, CCDF, crest factor, Pulse Measurements: Pulse Width, Pulse Peak Power, On/Off Ratio, Pulse Ripple, Pulse Repetition Interval, Duty Cycle Pulse-Pulse, Phase, Channel Power, Occupied BW, Frequency Deviation
Interface USB, LAN/GPIB
Operating Temperature 5 to 40 degree C and 80 % RH at 40 degree C
Power Requirements (230 +/- 10% VAC, 50 Hz) Yes
Rack Mount Kit For Signal Analyzer Yes
Availability Of The Test Report From Central Govt./ NABL/ ILAC Accredited Lab As Per Doc Correction Slip No. 38 Dtd 18/1/12 To Be Read In Conjunction With P&C Circular No. 71 Dtd 29/10/14 For Each Model Of Signal Analyzer. Yes
TTC No. & Date Prime/T&M-323 12/12/17
Name Of The Lab Prime Calibration
Address Of The Lab Laxmi Nagar, Delhi
Type Test Reports Shall Consist Of Verification Of All The Features & Functional Parameters & Environmental Tests. Yes
Dry Heat Test: For 16 Hrs At A Temp. Of 55 Degree C In Accordance With IS: 9000/part-3/section-5/1977 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
Cold Test: For 4 Hrs At A Temp. Of (-)10 Degree C In Accordance With IS: 9000/part-2/section-4/1977(reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
Damp Heat Test: For 2 Cycles Of 24 Hrs (12 + 12h) Each At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
The Scope Of Supply Shall Include One Set Of Operation And Maintenance Manual For Each Equipment. Yes