copy of copy of liebert gxt mt cx 1kva std. (liebert)(copy of copy of gxt mt cx 1kva std)

` 19,800.00

  • MRP: `22000.00

Liebert Make True ON LINE UPS MODEL- GXTMT CX 1KVA SBCapacity-1KVA / 800Watts With Built In Batteries for 10-20Mins Battery Back UP TIME12V-7AH-02Nos.Input Voltage - 110V-280VACBased On Load at 50Input Frequency 40HZ-70HZ. Input P.F.- 0.99@Nominal Voltage 100 Load. Output Voltage- 200V-/ 220V/230V/240V Total Hormonics Distortion 3 Linear Load. Charging Current Max.1Amp. Charging Voltage 54.7VDC / - 1 Warranty for UPS 24Months 6Months For Batteries.

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - MOSFET-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 216 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 1 KVA
Technology MOSFET-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 216 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer No (only for IGBT-PWM Technology)
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. E20151205E
Type Test Certificate Date 08/12/2015
Name Of Lab DOLGEGGUANLORE System Centre
Address Of Lab China
Supply & Commissioning 5
Warranty 1 Years