DC/AC voltages from 100 uV to1000V, with accuracy 0.5 percent, DC/AC currents from 10uA to 10.00A, with accuracy 1 percent, Resistance from 1 ohm to 40 M ohms with zero correction, Capacitance from 1pF ... 200.00 micro F with zero correction, Frequencies from 10 Hz to 500kHz, Diode measurement and continuity testing, Data Hold, Backlite Feature, Auto power off, Auto/Manual range Selection, Temperature measurement with K type Thermocouple, Automatic terminal blocking system, Protective holster for drop protection and Test/Calibration Certificate..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.08 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 100 % |
Capacitance Mreasurement Range | 1 to 100 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -40 to 400 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category II 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | -10 to 50 degree |
Operating Humidity (RH) | 45 to 75 |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 2 X 1.5 V Cells ALKALINE |
Total Voltage Of Battery | 3 |
Standard Accessories Supplied With The Equipment | 1 Multimeter, 1 Cable set, 1 Copy Operating Instructions, 1 Protective Case (Holster). |
Dimensions (H X W X L) | 86 mm x 188 mm x 53 mm With Holstar mm x mm x |
Weight | 480 gms gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | ERTL(W)/2007 E&S 142 |
Test Report Date | 21/08/2007 |
Name Of The Lab | ERTL |
Warranty | 1 Year |