Micro controller Based. MZDFMD comes with unique feature of text on video technology. Conform to relevant electric safety standard Supported by Test Certificates from NABL India or other accredited labs from the country of origin of the equipment including SHOCK, BUMP,, DURABILITY,IMPACT RESISTANCE as per IEC -61010. All the Detector Parameters like Sensitivity, Threshold, Metal Level and IN-OUT count is being displayed at a time in the LCD and Monitor. Having inbuilt recording capacity..
Other Specifications Download Specification | |
---|---|
Technology | Transmitter and Receiver |
Walk-through Arch (Outer Frame) Dimensions (H X W X D) | 2230x860x720 mmxmmxmm |
Walk-through Arch (Inner Frame) Dimensions (H X W X D) | 2000x720x720 mmxmmxmm |
Detection Area (H X W X D) | 2000x720x720 mmxmmxmm |
Detection Zones | Multiple Zones |
Number Of Detection Zones | 6 |
Type Of Usage | Indoor |
"Construction Of Door Frame (Walk-through Arch)" | Light weight, rigid, laminated side panels and cross piece with ABS plastic boots for panel protection |
Door Frame Is Provided With Base Wheels For Easy Mobility | NO |
Door Frame Is Provided With A Floor Panel To Attach Both Side Panels To Give Stability & Rigidity To The Structure | NO |
Ramp Over The Floor Panel - Covered With Synthetic Carpet For Long Life | NO |
Door Frame Material | ABS |
Door Frame Is Water Proof | NO |
Door Frame Is Weather Proof | YES |
Operational Frequency Range | LESS THAN 30 KHZ |
Number Of User Selectable Frequencies | 5 |
Adjustable Sensitivity | YES |
Number Of Sensitivity Levels / Steps | 0-255 |
Metals Which Can Be Detected | Ferrous, Non-Ferrous, Ferrite & Alloys |
Capability Of Metal Detection In Entire Frame Area | Uniformly in entire Frame Area |
Capability Of Metal Detection In All Orientations | YES |
Capability Of Metal Detection In Walking Speed Of Interception | YES |
Audio-Visual Indication On Detection At Side Panels And Control Panel | YES |
Audible Alarm On Detection With Adjustable Volume | YES |
Back-lit Display | LCD |
Display Of Zone Intercepted | YES |
False Alarm Rate | % |
Traffic Counter (inbound / Outbound) For Counting Number Of Persons Passing The Sensing Zone | YES |
Walk / Stop Indicator For Traffic Control | YES |
DFMD Should Not Interfere With Adjacent Installed DFMDs Within A Distance Of 1 Foot | YES |
DFMD Should Not Be Affected By Opening / Closing Of A Metallic Gate In Vicinity | YES |
DFMD Should Not Be Affected By Heavily Reinforced Floors / Roof Tops / Walls | YES |
DFMD Should Not Be Affected By External RF Transmission And EMI (Electro Magnetic Interference) | YES |
Capacity / Throughput Rate | 50 person/min |
In-built Auto Calibration Capability | YES |
User Friendly Self-testing Diagnostics To Identify Faulty Condition | YES |
Control Panel | Easy accessible control panel, with modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and / or by password. |
Power Supply | 220 V AC, 50 Hz, Mains + 10 |
Battery | Standard UPS |
"Details Of Battery / UPS (Type / Make / Capacity -VAH, Etc)" | OPTIONAL |
Battery Back-up In Full Function | 2 hrs hours |
Audio-Visual Low Battery Indicator | YES |
DFMD Should Be 'Data Safe' | YES |
DFMD Shall Be Harmless To Wearers Of Pacemakers, Defibrillators Or Other Vital Support Systems, Pregnant Women And Magnetic Storage Media (floppy Disks, Audio Cassettes, Video Cassettes And Similar) | YES |
DFMD Should Conform To International Security Standards Of Safety / Radiation | YES |
Warranty | 3 Years |
One Test Sample For Each Machine For Tesgting During Commissioning / Maintenance | Inclusive in the scope of supply |
Training Tools- Charts, Slides, Training Brochure, Training Work Model, Blowup Diagram, Video Films On Demonstration And Use Etc. | Inclusive in the scope of supply |
Technical Manual Giving Full Description Of The Item, User's Handbook And Literature On Preservation / Maintenance, Procedure For Packing, Handling, Transportation, Storage And Battery Replacement | Inclusive in the scope of supply |
Practical Training | At least one day in each quarter of the year continuing during warranty period |
Operating Temperature Range & Relative Humidity | -10 to + 70 deg C with humidity 95% non condensing |
Availability Of Spares For A Period Of 7 Years After The Warranty Period | YES |
Availability Of Test Reports From Central Govt / NABL / ILAC Accredited Lab Covering All The Parameters As Per Specifications | YES |
Test Report No. | EMI113 |
Name Of Test Lab | ERTL |
Address Of Test Lab | ANDHERI MUMBAI |
Hyper Link To Test Report | NOT AVAILABLE |