× All the transactions performed on 2.0 is available here. To access Market click "Home".

digital clamp meter (meco)(model-2250-hz-auto)

` 2,994.00

  • MRP: `3949.00

2250Hz AUTO 28-09-201231. SPECIFICATIONS1.1 General SpecificationDisplayn3 digit liquid crystal display LCD with amaximum reading of 3999.PolaritynAutomatic, positive implied, negative polarityindication.OverrangenOL or -OL is displayed.ZeronAutomatic.Low batteryn is displayed when the batteryindicationvoltage drops below the operating level.Measurementn3 times per second, nominal.rateOperatingn0C to 50C at 70 relative humidity.EnvironmentStoragen-20C to 60C, 0 to 80 R.H. with batteryTemperatureremoved from meter.AccuracynStated accuracy at 270C 50C,75 relative humidity.PowernTwo 1.5V AAA Size BatteryBattery lifen200 hours typicalDimensionsn250 x 98 x 35mm approx.Weightn400gms including battery approx.AccessoriesnPair of test leads x 1, instruction manual x 1,1.5V batterys installed x 2, Carring Case x 1.

  • Availability: 95 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - Backlit
  • Measurement Type - True RMS
  • AC Current Measurement Range - 0 to 999.9 Ampere
  • AC Voltage Measurement Range - 0 to 1000 Volt
  • Inrush Current (Integration Time) - 100 millisecon
Other Specifications Download Specification
Type Hand Held
Display Backlit
Measurement Type True RMS
AC Current Measurement Range 0 to 999.9 Ampere
AC Current Measurement Accuracy + or - 2 %
AC Voltage Measurement Range 0 to 1000 Volt
AC Voltage Measurement Accuracy Upto 600 Volts + or - 1 %
AC Voltage Measurement Accuracy Beyond 600 Volts + or - 1.5 %
Inrush Current (Integration Time) 100 millisecon
DC Current Measurement Range 0 to 999.9 Ampere
DC Current Measurement Accuracy + or - 2 %
DC Voltage Measurement Range 1000 Volt
DC Voltage Measurement Accuracy + or - 1 %
Resistance Measurement Range 0 to 4000 Ohm
Resistance Measurement Accuracy + or - 1.5 %
Continuity < or = 30 Ohm
Frequency Measurement Range 10 to 400
Frequency Measurement Accuracy + or - 0.5
Jaw Size (Dia In Closed State) 55 MM
Satety Rating Category III 600 V of IEC 61010 -2-D31
Operating Temperature Range 0°C to 50°C Degree C
Operating Humidity (RH) 80 %
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
Standard Accessories Supplied With The Equipment Pair of test leads x 1, instruction manual x 1, 1.5V batterys (installed) x 2, Carring Case x 1
Dimensions (H X W X L) 250 x 98 x 35mm (approx.) mm x mm x
Weight 400gms including battery (approx.) gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 895421
Test Report Date 12-12-2014
Name Of The Lab TAMTA
Warranty 1 Year

Price Dekho Price Dekho Price List in india