DIGITAL MULTIMETER Fluke 15B Maximum Voltage between any Terminal and Earth Ground 1000V Display Digital 4000 count updates 3/secTemperature Operating 0 C to 40 C, Storage -30 C to 60 C indefinitely to -40 C for 100 hoursOperating Altitude 0 to 2000 metersTemperature Coefficient 0.1 X specified accuracy/ C 18 C or 28 CElectromagnetic Compatibility Complies with FCC Part 15, Class B, IEC 61326, 3 V/m, performance criterion BRated Transient Overvoltage 4 kV 1.2 x 50 s Peak for measurement Categories I, II, and III. Relative Humidity Noncondensing 10 C 90 from 10 C to 30 C 75 from 30 C to 40 C Relative Humidity, 40 M Range 80 from 10 C to 30 C 70 from 30 C to 40 C Battery Type 2 X AA, NEDA 15A, IEC LR6 Battery Life Alkaline 500 Hours Size H x W x L 180 mm x 89 mm x 51.5 mm with holster Weight 425 grams Certifications CMC, PSafety Compliance.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.08 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 3 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 100 % |
Capacitance Mreasurement Range | 1 to 100 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -40 to 400 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category II 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0 ° C to 40 ° C, |
Operating Humidity (RH) | 80 |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 2 X AA, NEDA 15A, IEC LR6 |
Total Voltage Of Battery | 2 |
Standard Accessories Supplied With The Equipment | The Meter is designed to protect agains t transients in these catagories: CAT I CAT II CAT III From high-voltage low-energy sources, e.g., electronic circuits or a copy machine. From equipment supplied from the fixed installation, e.g., TVs, PCs, portable tools and household appliances. From equipment in fixed e |
Dimensions (H X W X L) | 180 mm x 89 mm x 51.5 mm (with holster) mm x mm x |
Weight | 425 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 869763 |
Test Report Date | 16-08-2015 |
Name Of The Lab | TANTA |
Warranty | 1 Year |