× All the transactions performed on 2.0 is available here. To access Market click "Home".

SUCTION MACHINE NEONATAL SLOW (Neovac)(Neovac)

` 13,899.00

  • MRP: `18500.00

Compact Design facilitatesmobility Rugged oil free Motorsuctioning Maximum Negative Pressureachieved 110 mm of Hg Canbe increased or reduced as perrequirement. Suction level controller knobprovided.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 1
  • "Definition:A portable assembly of devices primarily intended to be used by emergency medical services (EMS) to aspirate fluids,secretions, or other foreign materials from a patient's airway by means of suction. It typically consists of a gas powered mechanism driven by medical air or oxygen (O2) from a gas cylinder to create the suction (e.g., a venturi tube), tubing, a collection container, a vacuum gauge and control knob, and a microbial filter. The pump creates a vacuum in the suction tubing which is used for the removal of materials into the collection container. This system is typically used during patient transport or for emergency situations." - yes
  • Clinical purpose : to aspirate fluids, secretions, or other foreign materials from a patient's airway by means of suction. - yes
  • Technical characteristics (specific to this type of device) : 0-700 mm Hg ± 10 regulable, flutter free vacuum control knob, 25ltrs/min, tight fitting jar cap.Wide mouthed 2 x 2 Ltrs. (Poly carbonate) with self sealing bungs and mechanical over flow safety device. - yes
  • Dimensions (Height X Width X Length) Max. - 43 x 30 x 68 cm
  • Noise (in dBA) Max. - 50 dBA
Other Specifications Download Specification
GMDN Name & Code(s) Suction pump portable & CT 1272
"Definition:A Portable Assembly Of Devices Primarily Intended To Be Used By Emergency Medical Services (EMS) To Aspirate Fluids,secretions, Or Other Foreign Materials From A Patient's Airway By Means Of Suction. It Typically Consists Of A Gas Powered Mechanism Driven By Medical Air Or Oxygen (O2) From A Gas Cylinder To Create The Suction (e.g., A Venturi Tube), Tubing, A Collection Container, A Vacuum Gauge And Control Knob, And A Microbial Filter. The Pump Creates A Vacuum In The Suction Tubing Which Is Used For The Removal Of Materials Into The Collection Container. This System Is Typically Used During Patient Transport Or For Emergency Situations." yes
Clinical Purpose : To Aspirate Fluids, Secretions, Or Other Foreign Materials From A Patient's Airway By Means Of Suction. yes
Technical Characteristics (specific To This Type Of Device) : 0-700 Mm Hg ± 10 Regulable, Flutter Free Vacuum Control Knob, 25ltrs/min, Tight Fitting Jar Cap.Wide Mouthed 2 X 2 Ltrs. (Poly Carbonate) With Self Sealing Bungs And Mechanical Over Flow Safety Device. yes
User's Interface Manual
Dimensions (Height X Width X Length) Max. 43 x 30 x 68 cm
Weight (Max) 5 Kgs
Mobility, Portability yes
Noise (in DBA) Max. 50 dBA
Heat Dissipation: Should Maintain Upto 36.5 Deg Temp And The Heat Disbursed Through A Exhaust Fan yes
Operational Requirements : 230 V, 50 Hz, 2 ± 0.5 Amps . yes
Protection : Electrical Protection By Resettable Over Current Breakers Or Replaceable Fuses, Fitted In Both Live And Neutral Lines. yes
Power Consumption 200 Watts Watts
Accessories (mandatory, Standard, Optional);Spare Parts (main Ones) 5m tube
Consumables / Reagents (open, Closed System) open
Operating Condition:–Capable Of Operating Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90% In Ideal Circumstances. yes
Product Should Be FDA / CE Approved Product, ISO 13485:2003; ISO 10079-2-1999: Medical Suction Equipment - Part 1 : yes
Warranty 3 years
Training Of Staff (Medical, Paramedical, Technician) yes

Price Dekho Price Dekho Price List in india