insulation tester for analog-digital insulation and continuity testing (rishabh)(insu10)

` 3,949.00

  • MRP: `4395.50

Measurement of the insulation resistance on electrically deadequipment and systems with test voltages up to 1000V.For testing motors, transformers, generators, switchgears.For testing of house hold appliances.Measurement of the insulation resistance of cables.Very useful for on-site maintenance and service departments. Test Voltages 50V/ 100V/ 250V/ 500V/ 1000V, Insulation Resistance Measurement 10 KOhm ...999 MOhm .Hands-free continuity testing, Voltmeter greater than 25V ... 600 V AC/DC, Automatic discharge for capacitive circuits after test measurement, Live circuit detection, Pre-selectable measurement time for Insulation Resistance Measurement, Pre-selectable limit checks Go/ No-go option for M Ohm, Lead resistance null facility, Storage of MIN/MAX values, Storage Memory for last 50 readings, Blown fuse indication, Low battery indication, Stop Watch, Auto-power off function, Protective holster for rough duty, Low Resistances Measurement..

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection Inhibit test terminal voltage >30 V prior to initialization of test
Pass Fail Function Yes
Data Logging NA
Software Not Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 2 milliamper
Operating Temperature Range -20 to +40 Degree C
Operating Humidity (RH) 90 %
Power Requirements Battery Operated
Type Of Battery 6 X 1.5V IEC LR 6
PC Interface Available
Standard Accessories Supplied With The Equipment 1 Meter, 1 Cable Set, Round Pencil Cell-6nos, 1 Spare Fuse, 1 Belt, 1 User Manual, 1 Warranty Card, 1 Test Certificate, 1 Crocodile Clip set, 1 Safety Cover
Dimensions (H X W X L) 195 X 84 X 35 mm x mm x
Weight 500 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 128533
Test Report Date 23/12/2017
Name Of The Lab Star Labs
Warranty 1

Price Dekho Price Dekho Price List in india