Portable Dry Chemical Powder ABC type Fire Extinguisher comes fitted with squeeze grip type controllable discharge mechanism to provide flexibility of releasing extinguishing agent on targeted fire location.02. It contains MAP 90 with 90 Percent concentration of Mono Ammonium Phosphate.03. The extinguisher is ISI marked, EN PED approved and CE marked.04. The extinguisher has a unique grip integrated with a cap over the valve housing. The grip and the cap are constructed of Glass filled Nylon.05. It has a magnetic Pressure Gauge to enable the checking of pressure gauges correct working without dismantling or opening the cylinder.06. Vessel used in the manufacturing is constructed using Deep Drawn Technology to keep seamless area not less than 70 Percent of the cylinder, Hydrostatic Pressure Test and Helium Leak Detection Test certification will be provided along with supply.07. Serial no. and date of manufacturing is embossed on the body of the fire extinguisher...
Other Specifications Download Specification | |
---|---|
Conformity To Standard | "EN 3-7 + A1: 2007 & EN 3-8;2006 with latest amdnt. " |
Marine Equipment Directive(MED) Approved | No |
Type | Stored Pressure |
Trolley | Without Trolley |
Extinguishing Media | Powder Based |
Foam Based Extinguishing Media | NA |
Powder Based Extinguishing Media | ABC Powder |
Clean Agents Based Extinguishing Media | NA |
Halon Based Extinguishing Media ( As Per European Council Regulation 2037/2000 Concerning Use Of Halons) ( If Not Applicable Write NA) | NA |
Water Based Extinguishing Media ( If Not Applicable Write NA) | NA |
Wet Chemical Based Extinguishing Media ( If Not Applicable Write NA) | NA |
CO2 Based Extinguishing Media ( If Not Applicable Write NA) | NA |
Expellant Medium | N2 Based |
Class -A Fire Rating For (Powder Based, Water Based, Foam Based,Wet Chemical Based,CO2 Based,Halon Based Fire Extinguisher | 5A |
Class -B Fire Rating For (Powder Based, Foam Based CO2 Based Fire Extinguisher | 21B |
Nominal Permitted Charge For Powder Based Fire Extinguisher | 2 kg |
Nominal Permitted Charge For Water Based, Foam Based, Wet Chemical Fire Extinguisher | NA Ltrs |
Nominal Permitted Charge For C02 Based Fire Extinguisher | NA kg |
Nominal Permitted Charge For Halon Based Fire Extinguisher | NA kg |
Nominal Permitted Charge For Clean Agents Based Fire Extinguisher | NA kg |
Discharge Time | 9 second |
Discharge Range Of Fire Extinguisher | 2.5 meters |
Weight Of Filled Portable Fire Extinghuisher | 3.5 kg |
Operating Temperature, Max | 55 ° C |
Test Pressure(cylinder) | 35 Bar |
Height Of Cylinder | 344 mm |
Diameter Of Cylinder | 108 mm |
Rechargable | Yes |
Color Coding | Signal Red |
Fire Extinguisher Suitable For Class -C Fire | Yes |
Fire Extinguisher Suitable For Class -D Fire | No |
Fire Extinguisher Suitable For Class -K Fire | No |
Fire Extinguisher Suitable For Class -F Fire | Yes |
Availability Of Test Report From Central Govt./NABL/ILAC Acredited Lab To Prove Confirmity To Specification | Yes |
Test Report No. | a) 130025 b) 130005 contains MAP 90 ISI marked, EN PED approved and CE marked. a unique grip integrated with a cap over the valve housing constructed of Glass filled Nylon. Helium Leak Detection Test certification. |
Test Report Date | a) 21/06/2013 b) 06/06/2013 |
Name Of The Lab | a) and b) Fire Test & Research Laboratory |
Address Of The Lab | a) and b) 9th Milestone, SH-11, Sonipath-Gohana Road, Rattangarh, Sonipat-131001 |
Service Pressure | 15 Bar @ ° C |
Guarantee Against Corrosion | 5 Years |
Welding On The Extinguisher Body | Yes |
Cylinder/Bottle Material | Steel |