MI 3205 insulation teste 5 kv 15 tera ohm 6mA (Metrel)(MI 3205)

` 266,000.00

  • MRP: `312941.00

MI 3205 TeraOhm XA 5kV is a portable battery Li-ion or mains powered test instrument with excellent IP protection IP65 case closed and IP54 case open, intended for diagnosing of Insulation Resistance by using high test voltages of up to 5 kV. It is designed and produced with the extensive knowledge and experience acquired through many years of working in this field..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 200 K Ohm to 1 T Ohm
  • Test Voltage - 250, 500, 1000, 2500 and 5000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Portable
Measurement Range 200 K Ohm to 1 T Ohm
Test Voltage 250, 500, 1000, 2500 and 5000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection NA
Pass Fail Function Yes
Data Logging more than 99 locations
Software Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 2 milliamper
Operating Temperature Range -10 to 50 °C Degree C
Operating Humidity (RH) 90 % RH (0 D ÷ 40 D), non-condensing %
Power Requirements Battery Operated
Type Of Battery High power Li-ion battery
PC Interface Available
Standard Accessories Supplied With The Equipment 10 kV shielded test lead, 2 m, 2 pcs (black, red) • 10 kV crocodile clip, 2 pcs (black, red) • Guard test lead, green, 2 m • Crocodile clip, green • Mains cable • PC SW HVLink PRO with USB and RS 232 cable • Handbook “Guide to modern insulation testing” on CD • Instruction manual on CD • Calibration certificate
Dimensions (H X W X L) 345 x 160 x 335 mm mm x mm x
Weight 6500 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. MI3205
Test Report Date 10-07-14
Name Of The Lab Metrel DD Slovenia Europe
Warranty 1