mi 2892 poweer quality analyser three phase class a (metrel)(mi 2892 power master)

` 504,000.00

  • MRP: `592941.00

4-voltage channels with wide measurement range 0 ... 1000 Vrms CAT III / 1000 V 4-current channels with support for automatic clamp recognition and on instrument range selection Automatic Smart Clamp detection and Smart Clamp range selection Sampling frequency on transients recording49 k Samples/sec Compliance with power quality standard IEC61000-4-30 Class A Complete power quality analysis according to EN50160 including signalling and inter harmonics Support for micro SD memory card 8-GBsupplied with the instrument up to 32GB Color-coded input terminals and terminal labels to suit your application region Intuitive main menu and large icons that makes the equipment very easy to navigate and configure Current clamp auto range selection Powerful PC SW PowerView3 enables downloading,view, analysis of recorded data and professional report creation Flexible clamps without additional power supply are included in the Euro set Remote communication.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Display type - LCD Backlit
  • Display Mode - 4.3 inch color TFT (480 x 272)
  • Number of Current Channels - 4 Nos.
  • Facility to Measure RMS Voltage - Available
  • Measurable voltage resolution - 10 mV, 100mV Volts
Other Specifications Download Specification
Type Of Power Analyzer Three phase
Display Type LCD Backlit
Display Mode 4.3 inch color TFT (480 x 272)
Number Of Current Channels 4 Nos.
Number Of Voltage Channels 4 Nos.
Facility To Measure RMS Voltage Available
Measurable Voltage Range Phase (L-N): 50 ÷ 1000 VRMS Volts
Measurable Voltage Accuracy ±0.1% of nominal voltage,
Measurable Voltage Resolution 10 mV, 100mV Volts
Facility To Measure RMS Current Available
Measurable Current Range 50 m ÷ 1200 ARMS (with A1281 iron clamps) Ampere
Measurable Current Accuracy ±0.5% of m.v. (with A1281 iron clamps)
Measurable Current Resolution - Ampere
Facility To Measure Active, Reactive And Apparent Power Available
Maximum Power That Can Be Measured 0.000 k ÷ 999.9 M KW
Power Accuracy ±0.7 % P
Power Resolution - Watt
Facility To Measure Active, Reactive And Apparent Energy Available
Facility To Measure Sag(dips) And Swell(surge) Available
Facility To Measure Frequency Available
Frequency Range That Can Be Measured 42,5 ÷ 69,0 Hz ±10 mHz Hz
Facility To Measure Total Harmonic Distortion Available
Accuracy In Measurement Of Total Harmonics Distortion UhN
Resolution In Measurement Of Total Harmonics Distortion 10 mV
Facility To Measure Inter Harmonics Available
Order(n) To Which Facility To Measure Harmonics Available 0th > 50th
Facility To Measure Power Factor Available
Accuracy In Measurement Of Power Factor ± 0.02
Facility To Measure Distortion Factor Available
Accuracy In Measurement Of Distortion Factor -
Facility To Measure Ripple Factor Available
Accuracy In Measurement Of Ripple Factor -
Facility To Measure Voltage And Current Unbalance Available
Facility To Measure Inrush Current Available
Facility To Measure Flicker Available
Facility To Measure Crest Factor Available
Measurable Crest Factor Range 1.00 ÷ 2.50
Measurable Crest Factor Accuracy ± 5 % · CFU
Measurable Crest Factor Resolution 0.01
Screen Memory -
Data Transfer Software Provided For Analysis On PC Yes
Internal Memory External memory 8 GB micro SD card MB
Type Of Battery Used 1.2 V NiMH rechargeable batteries type HR 6 (AA)
Battery Backup 4 Hours
Power Supply(volts In AC) 230
Weight Of The Analyser 1000 Grams
Dimensions(LXWXH) 230 x 140 x 80 mm cmXcmXcm
Provision For External SD Card Yes
Operating Temperature Range -20 DC ÷ +55 DC degree celsius
Operating Humidity 95 % RH (0 DC ÷ 40 DC), non-condensing %
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer As per technical data Sheet
Compliance To IEC 61000-4-30 Yes
Category Of Safety Rating CAT-III 1000V,CAT-1V 600V
Dry Heat Test As Per IS :9000(Part 3/Section 5) Yes
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) Yes
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) Yes
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. Yes
Type Test Report No. MI2892
TTC Report Date 10-07-2014
Name Of Lab Metrel
Address Of Lab Slovania
Interface RS232, USB and Ethernet