Output power capacity 660Watts / 1.1 kVAMax Configurable Power Watts 660Watts / 1.1 kVANominal Output Voltage 230VEfficiency at Full Load 72.0 Output Frequency sync to mains 50 HzTopology Line InteractiveWaveform type Stepped approximation to a sinewaveTransfer Time 10ms typical 12ms maximumInputNominal Input Voltage 230VInput frequency 45 - 65 Hz auto sensingInput Connections India 3-pin 6ACord Length 1.52metersInput voltage range for main operations 145 - 290VNumber of Power Cords 1Efficiency at Full Load 72.0 Batteries RuntimeBattery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte leakproofTypical recharge time 6hoursRuntimeView Runtime Manual TableCommunications ManagementControl panel LED status display with On Line On Battery Replace Battery and Overload indicatorsAudible Alarm Alarm when on battery distinctive low battery alarm overload continuous tone alarmSurge Protection and FilteringSurge energy rating 255JoulesPh.
Other Specifications Download Specification | |
---|---|
Rating In KVA | 1.1 KVA |
Technology | MOSFET-PWM with inbuilt isolation transformer |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | single phase 230V ±1% sinewave,50Hz |
Backup Time | 30 Minutes |
Minimum VAH | 800 VAH |
Voltage Regulation From No Load To Full Load | .8 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 35% % |
Overall Efficiency | 90 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | With |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | 83000450 |
Type Test Certificate Date | 09/08/17 |
Name Of Lab | BIS |
Address Of Lab | DELHI |
Supply & Commissioning | YES |
Warranty | 1 Years |