Measuring range up to 100 G Ohm with test voltage from 100 to 2500 V. Polarisation Index PI and Dielectric Absorption Ratio DAR calculation.Measuring results are displayed in numeric and analogue representation.Guard test terminal for elimination of potential surface leakage currents.Automatic polarity reversal on continuity test.Large green and red lights of the LEDs for PASS / FAIL evaluation of test result.Suited for testing on CAT IV installations.Magnetic holder for fixing instrument on metal surfaces.Built-in battery charger.Two level memory structure for saving test results and parameters.Download of results via RS232 or USB cable directly to the PC with the help of the PC software Euro Link PRO.
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm |
Test Voltage | 50, 100, 250, 500 and 1000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | NA |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | 0°C ÷ 40 °C Degree C |
Operating Humidity (RH) | 95 % RH (0 DC ÷ 40 DC), non-condensing % |
Power Requirements | Battery Operated |
Type Of Battery | 1.2 V NiMh Rechargable size AA Type |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | Soft hand strap Test lead, 2 x 1.5 m Test probe, 2 pcs (black, red) Crocodile clip, 2 pcs (black, red) Power supply adapter + 6 NiMH rechargeable batteries, type AA Instruction manual on CD Short instruction manual Handbook on CD Calibration certificate |
Dimensions (H X W X L) | 140 x 80 x 230 mm mm x mm x |
Weight | 850 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | MI3121H |
Test Report Date | 10-07-2014 |
Name Of The Lab | Metrel DD |
Warranty | 1 |