Keysight 33611A 80MHz 1CH Function-Arbitrary WaveformGenerator with exclusive Trueform signal generation technology offermorecapability,fidelity andflexibility thanprevious generation Direct DigitalSynthesis generators. Usethemto accelerate your development process fromstarttofinish. compatible with KeysightBenchVuesoftware. Trueformtechnology offersUnmatched capabilities for generating a full range of signals for your most demanding measurements. Sine waves with 5x lower harmonic distortion for morepuresignals. Pulses upto80MHz with1psjitter for more precisetiming. 660MSa/s samplingrateforhigher time resolution arbitrary waveforms.14bit resolution with 1mVpp to10Vpp amplitude for greater amplitude accuracy.4MSa/channel standard waveform memory, optional 64MSa/channel for your longest waveforms.USB,LANLXI-Core,GPIB optional for quick and easy connectivity to PCornetwork.BenchVue Enabled.Control your waveform generator from your PC easily. Std3YearWarranty.Prices includingGST@18percent.
Other Specifications Download Specification | |
---|---|
Frequency Bandwidth (Sine Wave) | 10 mHz to 80 MHz |
No. Of Channels | 1 |
Standard Waveforms | Sine, Square, Pulse, Ramp, Noise, Sin(x)/x, Exponential rise/fall, Gussian, DC Offset |
Band Width Of Arbitrary Waveform Generator | 10 mHz to 25 MHz |
Sample Rate Of Arbitrary Waveform Generator | 250 Mega Samples/sec |
Record Length Of Arbitrary Waveform Generator | 128 Kilo Points |
Waveform Memory Of Arbitrary Waveform Generator | 4 Waveforms |
Vertical Resolution (Minimum) | 12 Bits |
Amplitude Range (at 50 Ohm Impedance) | 10 mV to 10 V pp |
Modulation | AM, FM, PM, FSK, Burst, PWM |
Interface | USB |
Display | Colour |
Standard Accessories (To Be Supplied) | Power Chord, USB Cable, Certificate of Calibration, Documentation CD |
Power Requirements | 230 V +/-10% AC, 50 Hz +/- 3% |
Operating Temperature Range | 0 to 55 Degree C Degree C Degree C |
Operating Humidity (RH) | 5% to 80% RH, non-condensing % % |
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. (Test Reports Are To Be Furnished When Demanded By Buyer)" | Yes |
Test Report No. | 33611AMY53301045 |
Test Report Date | 09-MAY-2017 |
Name Of The Lab | Keysight Technologies Malaysia |
Warranty | 3 Years |